Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F23%3A00570821" target="_blank" >RIV/68378271:_____/23:00570821 - isvavai.cz</a>
Výsledek na webu
<a href="https://hdl.handle.net/11104/0342159" target="_blank" >https://hdl.handle.net/11104/0342159</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2022.167608" target="_blank" >10.1016/j.nima.2022.167608</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker
Popis výsledku v původním jazyce
The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier.
Název v anglickém jazyce
Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker
Popis výsledku anglicky
The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
1872-9576
Svazek periodika
1045
Číslo periodika v rámci svazku
Jan
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
3
Strana od-do
167608
Kód UT WoS článku
000890677500004
EID výsledku v databázi Scopus
2-s2.0-85141307360