Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F24%3A00598890" target="_blank" >RIV/68378271:_____/24:00598890 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/24:00380943 RIV/00216208:11320/24:10494219
Výsledek na webu
<a href="https://hdl.handle.net/11104/0356468" target="_blank" >https://hdl.handle.net/11104/0356468</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/19/08/P08005" target="_blank" >10.1088/1748-0221/19/08/P08005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light
Popis výsledku v původním jazyce
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of nonuniformities in light collection, caused by deployment of photon detectors only within the anode planes.
Název v anglickém jazyce
Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light
Popis výsledku anglicky
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of nonuniformities in light collection, caused by deployment of photon detectors only within the anode planes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
19
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
42
Strana od-do
ad6432
Kód UT WoS článku
001381766600003
EID výsledku v databázi Scopus
2-s2.0-85200895495