Unusual annealing of charge collection efficiency of silicon strip detectors, ATLAS18, irradiated to high fluences with 23 GeV protons
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F25%3A00645411" target="_blank" >RIV/68378271:_____/25:00645411 - isvavai.cz</a>
Výsledek na webu
<a href="https://hdl.handle.net/11104/0375203" target="_blank" >https://hdl.handle.net/11104/0375203</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2025.170682" target="_blank" >10.1016/j.nima.2025.170682</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Unusual annealing of charge collection efficiency of silicon strip detectors, ATLAS18, irradiated to high fluences with 23 GeV protons
Popis výsledku v původním jazyce
Extensive studies were performed on highly irradiated ATLAS18 mini strip detectors to evaluate their annealing behaviour. Collected charge was measured after several steps of annealing at 60 degrees C. For detectors irradiated with neutrons or low energy protons the collected charge exhibited a beneficial effect of short-term annealing which was followed by a decrease in charge collection efficiency at longer annealing times. After irradiation with 23 GeV protons to fluences above Phi(eq) similar to 1.2 . 10(15) cm(-2), the collected charge remained unchanged or decreased after the first few tens of minutes of annealing. Edge-TCT measurements indicated that this unusual annealing behaviour is related to the double-peak electric field profile in the detector. Mixed irradiation with 23 GeV protons and neutrons to fluences matching the expected in the upgraded ATLAS experiment showed this unusual annealing effect will not impact the operation of the ITk strip detector.
Název v anglickém jazyce
Unusual annealing of charge collection efficiency of silicon strip detectors, ATLAS18, irradiated to high fluences with 23 GeV protons
Popis výsledku anglicky
Extensive studies were performed on highly irradiated ATLAS18 mini strip detectors to evaluate their annealing behaviour. Collected charge was measured after several steps of annealing at 60 degrees C. For detectors irradiated with neutrons or low energy protons the collected charge exhibited a beneficial effect of short-term annealing which was followed by a decrease in charge collection efficiency at longer annealing times. After irradiation with 23 GeV protons to fluences above Phi(eq) similar to 1.2 . 10(15) cm(-2), the collected charge remained unchanged or decreased after the first few tens of minutes of annealing. Edge-TCT measurements indicated that this unusual annealing behaviour is related to the double-peak electric field profile in the detector. Mixed irradiation with 23 GeV protons and neutrons to fluences matching the expected in the upgraded ATLAS experiment showed this unusual annealing effect will not impact the operation of the ITk strip detector.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
1872-9576
Svazek periodika
1080
Číslo periodika v rámci svazku
Nov
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
170682
Kód UT WoS článku
001512942700001
EID výsledku v databázi Scopus
2-s2.0-105007765528