Vlastnosti pixelového detektoru neutronů založeného na systému Medipix-2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F04%3A00106091" target="_blank" >RIV/68378297:_____/04:00106091 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Properties of Neutron Pixel Detector Based on Medipix-2 Device
Popis výsledku v původním jazyce
The neutron transmission radiography can serve as complementary diagnostic method to the X-ray radiography. It can produce contrast images of materials, which are indistinguishable in X-ray images. Good performance of a neutron detecting device is essential for the acquisition of high quality neutron images. Slow neutrons are captured and converted in a thin layer containing Li-6 to tritons and alpha particles which are subsequently detected by a silicon pixel detector Medipix-2. The detector performance was tested at the NEUTRA station of the Paul Scherrer Institute using a beam of slow neutrons. The spatial resolution, detection efficiency and other detector properties were determined and compared with several types of contemporary neutron imaging systems. The results demonstrate superior state of the Medipix-2 based neutron imager in terms of the spatial resolution, linearity and dynamic range. The system is very promising in applications for micro-neutron tomography
Název v anglickém jazyce
Properties of Neutron Pixel Detector Based on Medipix-2 Device
Popis výsledku anglicky
The neutron transmission radiography can serve as complementary diagnostic method to the X-ray radiography. It can produce contrast images of materials, which are indistinguishable in X-ray images. Good performance of a neutron detecting device is essential for the acquisition of high quality neutron images. Slow neutrons are captured and converted in a thin layer containing Li-6 to tritons and alpha particles which are subsequently detected by a silicon pixel detector Medipix-2. The detector performance was tested at the NEUTRA station of the Paul Scherrer Institute using a beam of slow neutrons. The spatial resolution, detection efficiency and other detector properties were determined and compared with several types of contemporary neutron imaging systems. The results demonstrate superior state of the Medipix-2 based neutron imager in terms of the spatial resolution, linearity and dynamic range. The system is very promising in applications for micro-neutron tomography
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Abstracts, Rome 2004, IEEE conference
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
54
Strana od-do
54
Název nakladatele
Nuclear & Plasma Sciences Society
Místo vydání
Řím
Místo konání akce
Řím
Datum konání akce
16. 10. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—