Material decomposition utilizing dual energy computed tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F15%3A00450483" target="_blank" >RIV/68378297:_____/15:00450483 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.ndt.net/events/DIR2015/app/content/Poster/80_Vavrik.pdf" target="_blank" >http://www.ndt.net/events/DIR2015/app/content/Poster/80_Vavrik.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Material decomposition utilizing dual energy computed tomography
Popis výsledku v původním jazyce
Generally, inspection of the carbon fibre reinforced composites with metal components is embraced due to significantly different attenuation coefficients of a metal and CFRP components. At least two snapshots have to be taken with different X ray spectrafor each CT projection to be able separate material components and/or to reduce so called metal artifacts. Related so called dual energy CT (DECT) method can be generally based on two principles: Utilizing two different X ray tube spectra with significantly different X-ray tube potentials and X-ray beam filters, not special requirementsfor X-ray detector; Splitting of the X-ray spectra into two (or more) bands utilizing energy thresholds which are set on the detector side (it supposes that detector hasthis ability as WidePix has). X-ray tube spectra can be shaped by the tube voltage and/or by X-ray beam filtering.
Název v anglickém jazyce
Material decomposition utilizing dual energy computed tomography
Popis výsledku anglicky
Generally, inspection of the carbon fibre reinforced composites with metal components is embraced due to significantly different attenuation coefficients of a metal and CFRP components. At least two snapshots have to be taken with different X ray spectrafor each CT projection to be able separate material components and/or to reduce so called metal artifacts. Related so called dual energy CT (DECT) method can be generally based on two principles: Utilizing two different X ray tube spectra with significantly different X-ray tube potentials and X-ray beam filters, not special requirementsfor X-ray detector; Splitting of the X-ray spectra into two (or more) bands utilizing energy thresholds which are set on the detector side (it supposes that detector hasthis ability as WidePix has). X-ray tube spectra can be shaped by the tube voltage and/or by X-ray beam filtering.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
AL - Umění, architektura, kulturní dědictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1219" target="_blank" >LO1219: Udržitelný pokročilý rozvoj CET</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů