In-situ compression test of artificial bone foams in controlled environment using X-Ray micro-computed tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F19%3A00505071" target="_blank" >RIV/68378297:_____/19:00505071 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/APP/article/view/6024" target="_blank" >https://ojs.cvut.cz/ojs/index.php/APP/article/view/6024</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2019.25.0048" target="_blank" >10.14311/APP.2019.25.0048</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In-situ compression test of artificial bone foams in controlled environment using X-Ray micro-computed tomography
Popis výsledku v původním jazyce
In this study, we investigated specimens of artificial bone foams, developed by the research group for surgical simulators at the UAS Linz, which are used to mimic the haptic feedback of physiologic and pathologic bone for more realistic surgery training. Specimens with two kinds of mineral filler material as well as different amounts of foaming agent were tested in an environmental in-situ loading stage developed by the ITAM CAS and scanned via X-ray micro-computed tomography. In this in-situ stage, specimens can be immersed in liquid and tested under temperature-controlled conditions. Consequently, a total amount of 12 specimens was subjected to compression loading, half of them immersed in water at 36.5 °C and half in dry condition. Results showed that there is no significant influence of liquid immersion to the compression outcome. However, foams with less amount of foaming agent appeared to have smaller pores resulting in higher compression strength.
Název v anglickém jazyce
In-situ compression test of artificial bone foams in controlled environment using X-Ray micro-computed tomography
Popis výsledku anglicky
In this study, we investigated specimens of artificial bone foams, developed by the research group for surgical simulators at the UAS Linz, which are used to mimic the haptic feedback of physiologic and pathologic bone for more realistic surgery training. Specimens with two kinds of mineral filler material as well as different amounts of foaming agent were tested in an environmental in-situ loading stage developed by the ITAM CAS and scanned via X-ray micro-computed tomography. In this in-situ stage, specimens can be immersed in liquid and tested under temperature-controlled conditions. Consequently, a total amount of 12 specimens was subjected to compression loading, half of them immersed in water at 36.5 °C and half in dry condition. Results showed that there is no significant influence of liquid immersion to the compression outcome. However, foams with less amount of foaming agent appeared to have smaller pores resulting in higher compression strength.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Inženýrské aplikace fyziky mikrosvěta</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acta Polytechnica CTU Proceedings
ISBN
978-80-01-06670-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
48-51
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Telč
Datum konání akce
6. 6. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—