Comparison of fundamental natural modes of cantilevered beam obtained by 3D X-ray computed tomography and laser Doppler vibrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F24%3A00645212" target="_blank" >RIV/68378297:_____/24:00645212 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of fundamental natural modes of cantilevered beam obtained by 3D X-ray computed tomography and laser Doppler vibrometry
Popis výsledku v původním jazyce
This paper presents the pilot results and evaluation of the suitability of 3D X-ray computed tomography (XCT) for a modal analysis of the small specimens. The determination of a fundamental mode is illustrated on an example of a cantilever beam under a kinematic harmonic resonance excitation. The beam is excited by an electromagnetic voice-coil actuator mounted on the rotary stage of the XCT setup. The ability to rotate the oscillating specimen allows 3D motion to be captured by XCT and also provides accurate volumetric data of the imperfection beam, which is used for numerical calculation of the modal properties by the FEM model. The innovative XCT method provides results of the 3D modal shape of the deformed beam with nonlinearities, imperfections and defects that are hidden to other measurement methods. Validation of the XCT method is provided by a well-known Laser Doppler Vibrometry (LDV) and numerical calculations based on FEM models.
Název v anglickém jazyce
Comparison of fundamental natural modes of cantilevered beam obtained by 3D X-ray computed tomography and laser Doppler vibrometry
Popis výsledku anglicky
This paper presents the pilot results and evaluation of the suitability of 3D X-ray computed tomography (XCT) for a modal analysis of the small specimens. The determination of a fundamental mode is illustrated on an example of a cantilever beam under a kinematic harmonic resonance excitation. The beam is excited by an electromagnetic voice-coil actuator mounted on the rotary stage of the XCT setup. The ability to rotate the oscillating specimen allows 3D motion to be captured by XCT and also provides accurate volumetric data of the imperfection beam, which is used for numerical calculation of the modal properties by the FEM model. The innovative XCT method provides results of the 3D modal shape of the deformed beam with nonlinearities, imperfections and defects that are hidden to other measurement methods. Validation of the XCT method is provided by a well-known Laser Doppler Vibrometry (LDV) and numerical calculations based on FEM models.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-13811S" target="_blank" >GA22-13811S: Inovativní defektoskopická metoda založená na tomografické analýze vlastních tvarů kmitání ve 3D</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of ISMA2024 International conference on noise and vibration engineering USD2024 International conference on uncertainty in structural dynamics
ISBN
978-90-82893-17-5
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
842-851
Název nakladatele
KU Leuven
Místo vydání
Leuven
Místo konání akce
Leuven
Datum konání akce
9. 9. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce