Experimental Analysis of an Interior Thermal Insulation System on the Mineral Wool Basis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F02%3A01075449" target="_blank" >RIV/68407700:21110/02:01075449 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental Analysis of an Interior Thermal Insulation System on the Mineral Wool Basis
Popis výsledku v původním jazyce
A semi-scale device for the analysis of hygrothermal performance of building envelopes in the conditions of difference climate is employed for testing two selected interior thermal insulation systems, namely the brick wall and calcareous marly limestonewall with a newly developed capillary active mineral wool materials MU and DU (Rockwool, SA) as thermal insulation. In the testing process, the thickness of the specimens of building envelopes is the same as in the practical application on building site.The applied exterior climatic data correspond to the reference year data for Munich, Germany, for the interior climate common data for residential houses are chosen. A sophisticated technology for the determination of moisture, relative humidity, capillary pressure, temperature and salinity in the analyzed specimens based on the application of time-domain reflectometry, mini-tensiometry and mini-hygrometry is employed
Název v anglickém jazyce
Experimental Analysis of an Interior Thermal Insulation System on the Mineral Wool Basis
Popis výsledku anglicky
A semi-scale device for the analysis of hygrothermal performance of building envelopes in the conditions of difference climate is employed for testing two selected interior thermal insulation systems, namely the brick wall and calcareous marly limestonewall with a newly developed capillary active mineral wool materials MU and DU (Rockwool, SA) as thermal insulation. In the testing process, the thickness of the specimens of building envelopes is the same as in the practical application on building site.The applied exterior climatic data correspond to the reference year data for Munich, Germany, for the interior climate common data for residential houses are chosen. A sophisticated technology for the determination of moisture, relative humidity, capillary pressure, temperature and salinity in the analyzed specimens based on the application of time-domain reflectometry, mini-tensiometry and mini-hygrometry is employed
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Tagungsbeiträge Proceedings
ISBN
3-86005-322-1
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
634-642
Název nakladatele
Technische Universität Dresden
Místo vydání
Dresden
Místo konání akce
Dresden
Datum konání akce
26. 9. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce