Semi-Scale Testing of Interior Thermal Insulation System on Mineral Wool Basis
Popis výsledku v původním jazyce
In this paper, semi-scale testing of hygrothermal performance of building envelopes in the conditions of difference climate was employed for testing two selected interior thermal insulation systems, namely the brick wall and calcareous marly limestone wall with newly developed capillary active mineral wool materials (Rockwool, SA) as thermal insulation. The semi-scale experiment was done using the measuring system NONSTAT, which consists of two climatic chambers, connected by a specially developed tunnel for testing of specimens in large scale, devices for measuring relative humidity and temperature and devices for measurements of moisture content, salt content and capillary pressure. In the testing process, the thickness of the specimens of building envelopes is the same as in the practical application on building site, the applied exterior climatic data correspond to the reference year data for Munich, Germany, for the interior climate common data for residential houses are chosen
Název v anglickém jazyce
Semi-Scale Testing of Interior Thermal Insulation System on Mineral Wool Basis
Popis výsledku anglicky
In this paper, semi-scale testing of hygrothermal performance of building envelopes in the conditions of difference climate was employed for testing two selected interior thermal insulation systems, namely the brick wall and calcareous marly limestone wall with newly developed capillary active mineral wool materials (Rockwool, SA) as thermal insulation. The semi-scale experiment was done using the measuring system NONSTAT, which consists of two climatic chambers, connected by a specially developed tunnel for testing of specimens in large scale, devices for measuring relative humidity and temperature and devices for measurements of moisture content, salt content and capillary pressure. In the testing process, the thickness of the specimens of building envelopes is the same as in the practical application on building site, the applied exterior climatic data correspond to the reference year data for Munich, Germany, for the interior climate common data for residential houses are chosen
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Workshop 2003
ISBN
80-01-02708-2
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
934-935
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
10. 2. 2003
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—