Capillary Active Materials on the Mineral Wool Basis in Interior Thermal Insulation Systems: Computational Simulation of Hygrothermal Performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F02%3A01075470" target="_blank" >RIV/68407700:21110/02:01075470 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary Active Materials on the Mineral Wool Basis in Interior Thermal Insulation Systems: Computational Simulation of Hygrothermal Performance
Popis výsledku v původním jazyce
Hygrothermal performance of a three layer interior thermal insulation system consisting of water vapor retarder, capillary active thermal insulation material on the mineral wool basis and internal light plaster is tested by computational analysis using DELPHIN 4.1. Three types of load bearing structures are chosen in the calculations, namely the brick wall, limestone wall and concrete wall. As the capillary active thermal insulation, the dual density material DU developed by Rockwool, SA, is chosen, which meets the specific thermal, hygric and mechanical requirements to the interior thermal insulations. Temperature, relative humidity and overhygroscopic moisture fields are calculated for the time period of several years and the hygrothermal performanceof the systems is assessed. The calculations are first performed for the load bearing structure without any thermal insulation in order to find realistic initial conditions, then calculations for the particular renovated walls are done
Název v anglickém jazyce
Capillary Active Materials on the Mineral Wool Basis in Interior Thermal Insulation Systems: Computational Simulation of Hygrothermal Performance
Popis výsledku anglicky
Hygrothermal performance of a three layer interior thermal insulation system consisting of water vapor retarder, capillary active thermal insulation material on the mineral wool basis and internal light plaster is tested by computational analysis using DELPHIN 4.1. Three types of load bearing structures are chosen in the calculations, namely the brick wall, limestone wall and concrete wall. As the capillary active thermal insulation, the dual density material DU developed by Rockwool, SA, is chosen, which meets the specific thermal, hygric and mechanical requirements to the interior thermal insulations. Temperature, relative humidity and overhygroscopic moisture fields are calculated for the time period of several years and the hygrothermal performanceof the systems is assessed. The calculations are first performed for the load bearing structure without any thermal insulation in order to find realistic initial conditions, then calculations for the particular renovated walls are done
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Tagungsbeiträge Proceedings
ISBN
3-86005-322-1
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
585-594
Název nakladatele
Technische Universität Dresden
Místo vydání
Dresden
Místo konání akce
Dresden
Datum konání akce
26. 9. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—