Hygrothermal Performance of Interior Thermal Insulation Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F02%3A01078762" target="_blank" >RIV/68407700:21110/02:01078762 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygrothermal Performance of Interior Thermal Insulation Systems
Popis výsledku v původním jazyce
Hygrothermal performance of a three layer interior thermal insulation system consisting of water vapor retarder, capillary active thermal insulation material on the mineral wool basis and internal light plaster is tested by computational analysis using DELPHIN 4.1 As the capillary active thermal insulation, the dual density material DU developed by Rockwool, SA is used. Temperature, relative humidity and overhygroscopic moisture fields are calculated for the time period of several years and the hygrothermal performance of the system is assessed. Computational results show a very good hygrothermal performance of the chosen interior thermal insulation system for a brick wall, no overhygroscopic moisture appears in the structure during the period of fiveconsecutive years
Název v anglickém jazyce
Hygrothermal Performance of Interior Thermal Insulation Systems
Popis výsledku anglicky
Hygrothermal performance of a three layer interior thermal insulation system consisting of water vapor retarder, capillary active thermal insulation material on the mineral wool basis and internal light plaster is tested by computational analysis using DELPHIN 4.1 As the capillary active thermal insulation, the dual density material DU developed by Rockwool, SA is used. Temperature, relative humidity and overhygroscopic moisture fields are calculated for the time period of several years and the hygrothermal performance of the system is assessed. Computational results show a very good hygrothermal performance of the chosen interior thermal insulation system for a brick wall, no overhygroscopic moisture appears in the structure during the period of fiveconsecutive years
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
4th Ph.D. Symposium in Civil Engineering
ISBN
3-935065-09-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
8-13
Název nakladatele
Springer VDI Verlag
Místo vydání
Düsseldorf
Místo konání akce
Mnichov
Datum konání akce
19. 9. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce