Semi-scale testování a počítačové simulace vlhkostně-tepelné funkce při řízení obsahu vlhkosti v obvodových pláštích
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F04%3A01097186" target="_blank" >RIV/68407700:21110/04:01097186 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Semi-Scale Testing and Computer Simulations of Hygrothermal Performance in Moisture Management of Building Envelopes
Popis výsledku v původním jazyce
Semi-scale experiments for testing hygrothermal performance of building envelopes present a logical bridge filling the gap between the laboratory measurements of hygrothermal properties and full-scale test house measurements of field variables of heat and moisture transport. A semi-scale measuring system for determination of temperature and moisture fields should be designed in such a way that it simulates conditions, which are as close as possible to the real conditions on building site, but it shouldstill maintain its laboratory character, so that the expenses can be kept considerably lower compared to the real test house. In this paper, a 2-D critical semi-scale experiment is employed for obtaining basic information on hygrothermal performance of building envelope provided by newly designed interior thermal insulation system on the basis of hydrophilic mineral wool, aimed to the moisture management. The computational analysis of investigated building envelope is done using the com.
Název v anglickém jazyce
Semi-Scale Testing and Computer Simulations of Hygrothermal Performance in Moisture Management of Building Envelopes
Popis výsledku anglicky
Semi-scale experiments for testing hygrothermal performance of building envelopes present a logical bridge filling the gap between the laboratory measurements of hygrothermal properties and full-scale test house measurements of field variables of heat and moisture transport. A semi-scale measuring system for determination of temperature and moisture fields should be designed in such a way that it simulates conditions, which are as close as possible to the real conditions on building site, but it shouldstill maintain its laboratory character, so that the expenses can be kept considerably lower compared to the real test house. In this paper, a 2-D critical semi-scale experiment is employed for obtaining basic information on hygrothermal performance of building envelope provided by newly designed interior thermal insulation system on the basis of hydrophilic mineral wool, aimed to the moisture management. The computational analysis of investigated building envelope is done using the com.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of CIB World Building Congress 2004
ISBN
0-662-36716-2
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
"79-1"-"79-11"
Název nakladatele
IRC NRC
Místo vydání
Ottawa
Místo konání akce
Toronto
Datum konání akce
1. 5. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—