On the Influence of Sun Radiation to the Deformation of St. Vitus' Cathedral, Prague
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F07%3A00134608" target="_blank" >RIV/68407700:21110/07:00134608 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the Influence of Sun Radiation to the Deformation of St. Vitus' Cathedral, Prague
Popis výsledku v původním jazyce
This paper deals with the influence of solar radiation on the deformations of Saint Vitus' Cathedral, which falls within the UNESCO World Heritage reserve. For future preservation of the Cathedral it is important to determine potential displacements of its load bearing structure, which can be done by geodetic measurement. It was supposed that the measured displacements were caused by the temperature extensibility of Saint Vitus' masonry. Theoretical analysis of the displacements requires the best possible approximation of temperature differences inside the structure between the particular stages of measurement of these deformations. Numerical simulation with the influence of solar radiation was used for this purpose. The comparison of the computed and measured values (of displacements) confirmed the hypothesis that the measured displacements were mainly caused by the temperature extensibility of the structure.
Název v anglickém jazyce
On the Influence of Sun Radiation to the Deformation of St. Vitus' Cathedral, Prague
Popis výsledku anglicky
This paper deals with the influence of solar radiation on the deformations of Saint Vitus' Cathedral, which falls within the UNESCO World Heritage reserve. For future preservation of the Cathedral it is important to determine potential displacements of its load bearing structure, which can be done by geodetic measurement. It was supposed that the measured displacements were caused by the temperature extensibility of Saint Vitus' masonry. Theoretical analysis of the displacements requires the best possible approximation of temperature differences inside the structure between the particular stages of measurement of these deformations. Numerical simulation with the influence of solar radiation was used for this purpose. The comparison of the computed and measured values (of displacements) confirmed the hypothesis that the measured displacements were mainly caused by the temperature extensibility of the structure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F07%2F1522" target="_blank" >GA103/07/1522: Stabilita historických objektů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Eleventh International Conference on Civil, Structural and Environmental Engineering Computing
ISBN
978-1-905088-15-7
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
1-1
Název nakladatele
Civil-Comp Press Ltd
Místo vydání
Stirling
Místo konání akce
St. Julians
Datum konání akce
18. 9. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—