Influence of temperature to the deformations of historical buildings in Prague Castle
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F09%3A00162582" target="_blank" >RIV/68407700:21110/09:00162582 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of temperature to the deformations of historical buildings in Prague Castle
Popis výsledku v původním jazyce
This paper deals with the influence of temperature on the deformations of the ancient buildings in the area of Prague Castle, which falls within the UNESCO World Heritage reserve. For early detection of possible degradation process of these buildings itis important to do geodetic monitoring of the load bearing structure. During this monitoring were detected displacements among monitoring points. It was supposed that the measured displacements were caused by the temperature extensibility of ancient masonry. Theoretical thermo-mechanical simulation of temperature distribution in the structures in the time of geodetic measurement was obtained from 3-D numerical model of one span of the Saint Vitus Cathedral. The comparison of the computed and measured values of displacements confirmed the hypothesis that the measured displacements were caused also by the temperature extensibility of the structure.
Název v anglickém jazyce
Influence of temperature to the deformations of historical buildings in Prague Castle
Popis výsledku anglicky
This paper deals with the influence of temperature on the deformations of the ancient buildings in the area of Prague Castle, which falls within the UNESCO World Heritage reserve. For early detection of possible degradation process of these buildings itis important to do geodetic monitoring of the load bearing structure. During this monitoring were detected displacements among monitoring points. It was supposed that the measured displacements were caused by the temperature extensibility of ancient masonry. Theoretical thermo-mechanical simulation of temperature distribution in the structures in the time of geodetic measurement was obtained from 3-D numerical model of one span of the Saint Vitus Cathedral. The comparison of the computed and measured values of displacements confirmed the hypothesis that the measured displacements were caused also by the temperature extensibility of the structure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F07%2F1522" target="_blank" >GA103/07/1522: Stabilita historických objektů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computational Methods for Coupled Problems in Science and Engineering III
ISBN
978-84-96736-65-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
International Center for Numerical Methods in Engineering (CIMNE)
Místo vydání
Barcelona
Místo konání akce
Ischia
Datum konání akce
8. 6. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—