Hygro-thermal performance of earth-to-air heat exchanger: long-term data evaluation and short-term simulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F07%3A00137993" target="_blank" >RIV/68407700:21110/07:00137993 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygro-thermal performance of earth-to-air heat exchanger: long-term data evaluation and short-term simulation
Popis výsledku v původním jazyce
The thermal comfort requirements and cooling energy demand have significantly increased during the last twenty years. Air heating and/or cooling in an earth-to-air heat exchanger (EAHX) is a possible approach for improvement of thermal comfort in a building and for reduction of ventilation heat loss. A passive family house using mechanical ventilation system equipped with heat recovery and simple EAHX is being monitored since the end of summer 2005. The paper deals with the evaluation of measured data collected during year 2006. Amongst others, the results show the tendencies in moisture performance of monitored EAHX. Besides pure data evaluation, the short-term hygro-thermal simulation of EAHX was performed with a numerical model specially developed for this purpose. The simulation is compared with the monitored data; the comparison serves as the basic experimental validation of the model.
Název v anglickém jazyce
Hygro-thermal performance of earth-to-air heat exchanger: long-term data evaluation and short-term simulation
Popis výsledku anglicky
The thermal comfort requirements and cooling energy demand have significantly increased during the last twenty years. Air heating and/or cooling in an earth-to-air heat exchanger (EAHX) is a possible approach for improvement of thermal comfort in a building and for reduction of ventilation heat loss. A passive family house using mechanical ventilation system equipped with heat recovery and simple EAHX is being monitored since the end of summer 2005. The paper deals with the evaluation of measured data collected during year 2006. Amongst others, the results show the tendencies in moisture performance of monitored EAHX. Besides pure data evaluation, the short-term hygro-thermal simulation of EAHX was performed with a numerical model specially developed for this purpose. The simulation is compared with the monitored data; the comparison serves as the basic experimental validation of the model.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0579" target="_blank" >1M0579: Centrum integrovaného navrhování progresivních stavebních konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů