Pokročilá simulace zemních výměníků tepla - porovnání simulace s měřením
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F07%3A01137980" target="_blank" >RIV/68407700:21110/07:01137980 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advanced simulation of the earth-to-air heat exchangers - a comparison between simulation and measured data
Popis výsledku v původním jazyce
The paper deals with the earth-to-air heat exchanger (EAHX) simulation and monitoring. A newly developed hygro-thermal model for transient simulation of earth-to-air heat exchangers has already been validated against an analytical solution; a comparisonwith performance data of real EAHXs has missed so far. The model is tested against long-term monitoring of two simple earth-to-air heat exchangers connected with mechanical ventilation in two low-energy family houses. In parallel, the differential sensitivity analysis is used for a model assessment. The comparison between measured data and numerical simulation does not correlate absolutely. However, the simulation is capable to show limitations and energy saving potential of the exchanger with respect to building ventilation. The model brings clear information about processes which take place during earth-to-air heat exchanger operation.
Název v anglickém jazyce
Advanced simulation of the earth-to-air heat exchangers - a comparison between simulation and measured data
Popis výsledku anglicky
The paper deals with the earth-to-air heat exchanger (EAHX) simulation and monitoring. A newly developed hygro-thermal model for transient simulation of earth-to-air heat exchangers has already been validated against an analytical solution; a comparisonwith performance data of real EAHXs has missed so far. The model is tested against long-term monitoring of two simple earth-to-air heat exchangers connected with mechanical ventilation in two low-energy family houses. In parallel, the differential sensitivity analysis is used for a model assessment. The comparison between measured data and numerical simulation does not correlate absolutely. However, the simulation is capable to show limitations and energy saving potential of the exchanger with respect to building ventilation. The model brings clear information about processes which take place during earth-to-air heat exchanger operation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0579" target="_blank" >1M0579: Centrum integrovaného navrhování progresivních stavebních konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
12th Symposium for Building Physics
ISBN
978-3-86005-564-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
144-151
Název nakladatele
TU Dresden
Místo vydání
Dresden
Místo konání akce
Dresden
Datum konání akce
29. 3. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—