Measurement of Moisture Transport through Perforated Vapour Barriers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F08%3A00158663" target="_blank" >RIV/68407700:21110/08:00158663 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Moisture Transport through Perforated Vapour Barriers
Popis výsledku v původním jazyce
In the European Standards EN 15026 and EN ISO 13788, moisture transport in building envelopes is assumed one dimensional. In fact, three-dimensional moisture transport occurs due to layer perforation or building assembly details. The article is focused on cases of flat roofs where the vapour barrier is perforated. Water vapour permeability measurement of different vapour barriers with different degrees of perforation is done by the wet-cup method. Results are presented. A significant increase of moisture transport is found through vapour barriers which are perforated. A note on setting the apparatus to measure materials with very high water vapour resistance factor is presented. Finally, based on the results we discussed new recommendations to design more efficient flat roofs and avoid future failures.
Název v anglickém jazyce
Measurement of Moisture Transport through Perforated Vapour Barriers
Popis výsledku anglicky
In the European Standards EN 15026 and EN ISO 13788, moisture transport in building envelopes is assumed one dimensional. In fact, three-dimensional moisture transport occurs due to layer perforation or building assembly details. The article is focused on cases of flat roofs where the vapour barrier is perforated. Water vapour permeability measurement of different vapour barriers with different degrees of perforation is done by the wet-cup method. Results are presented. A significant increase of moisture transport is found through vapour barriers which are perforated. A note on setting the apparatus to measure materials with very high water vapour resistance factor is presented. Finally, based on the results we discussed new recommendations to design more efficient flat roofs and avoid future failures.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
The Nordic Journal of Building Physics
ISSN
1402-5728
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
SE - Švédské království
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—