Měření transportu vlhkosti skrze proděravěné parotěsnící zábrany
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F08%3A01146835" target="_blank" >RIV/68407700:21110/08:01146835 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Moisture Transport through Perforated Vapour Barriers
Popis výsledku v původním jazyce
In the European Standards EN 15026 and EN ISO 13788, moisture transport in building envelopes is assumed one dimensional. In fact, three-dimensional moisture transport occurs due to layer perforation or building assembly details. The article is focused on cases of flat roofs where the vapour barrier is perforated. Water vapour permeability measurement of different vapour barriers with different degrees of perforation is done by the wet-cup method. Results are presented. A significant increase of moisture transport is found through vapour barriers which are perforated. A note on setting the apparatus to measure materials with very high water vapour resistance factor is presented. Finally, based on the results we discussed new recommendations to design more efficient flat roofs and avoid future failures.
Název v anglickém jazyce
Measurement of Moisture Transport through Perforated Vapour Barriers
Popis výsledku anglicky
In the European Standards EN 15026 and EN ISO 13788, moisture transport in building envelopes is assumed one dimensional. In fact, three-dimensional moisture transport occurs due to layer perforation or building assembly details. The article is focused on cases of flat roofs where the vapour barrier is perforated. Water vapour permeability measurement of different vapour barriers with different degrees of perforation is done by the wet-cup method. Results are presented. A significant increase of moisture transport is found through vapour barriers which are perforated. A note on setting the apparatus to measure materials with very high water vapour resistance factor is presented. Finally, based on the results we discussed new recommendations to design more efficient flat roofs and avoid future failures.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 8th Symposium on Building Physics in the Nordic Countries
ISBN
978-87-7877-265-7
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Technical University of Denmark, BYG.DTU
Místo vydání
Lyngby
Místo konání akce
Copenhagen
Datum konání akce
16. 6. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—