VERIFIKACE VLIVU VYUŽITÍ DRUHOTNÉHO TEPLA VĚTRACÍHO VZDUCHU VE STÁJI PRO VÝKRM BROJLEROVÝCH KUŘATA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F08%3A01146630" target="_blank" >RIV/68407700:21110/08:01146630 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41310/08:24742
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Verification of the Effects of the Secondary Heat Recovery from Ventilation Air in an Animal House for the Fattening of Broiler Chickens
Popis výsledku v původním jazyce
The calculation of the thermal balance of the animal house documents that the power management system that includes a heat recovery exchanger unit may reduce the thermal capacity of external sources of heat in the animal house by 26.5% even when subjectto extreme conditions and at the atmospheric temperature of -12 °C and the age of chickens being 1 day. The results of the metering and calculations of the efficiency have proven that the heat exchanger reaches the operational efficiency of 10 - 47% andthermal efficiency of 20 - 80 % even during the most demanding operational first twenty days of the breeding cycle of broiler chickens. The specific consumption of energy for space heating and ventilation related to 1 kg of the live weight of chicken inthe animal house facility A provided with a heat recovery exchanger unit at the average atmospheric temperature during the cycle being 4.3 °C amounted to 278.5 Wh.
Název v anglickém jazyce
Verification of the Effects of the Secondary Heat Recovery from Ventilation Air in an Animal House for the Fattening of Broiler Chickens
Popis výsledku anglicky
The calculation of the thermal balance of the animal house documents that the power management system that includes a heat recovery exchanger unit may reduce the thermal capacity of external sources of heat in the animal house by 26.5% even when subjectto extreme conditions and at the atmospheric temperature of -12 °C and the age of chickens being 1 day. The results of the metering and calculations of the efficiency have proven that the heat exchanger reaches the operational efficiency of 10 - 47% andthermal efficiency of 20 - 80 % even during the most demanding operational first twenty days of the breeding cycle of broiler chickens. The specific consumption of energy for space heating and ventilation related to 1 kg of the live weight of chicken inthe animal house facility A provided with a heat recovery exchanger unit at the average atmospheric temperature during the cycle being 4.3 °C amounted to 278.5 Wh.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP103%2F08%2FP358" target="_blank" >GP103/08/P358: Metoda hodnocení efektivnosti zařízení pro zpětné získávání tepla ve větracích systémech pomocí metody exergií tepelných toků.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Infrastruktura i ekologia terenow wiejskich
ISSN
1732-5587
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—