Natural Ventilation of the Double Transparent Facade Cavity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F13%3A00209941" target="_blank" >RIV/68407700:21110/13:00209941 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Natural Ventilation of the Double Transparent Facade Cavity
Popis výsledku v původním jazyce
The modelling and simulation of the double façade transparent cavity is a complicated task. There are a lot of different elements which have influence over the function of the cavity. One important task is how the double façade transparent cavity is participated on the HVAC strategy. There is origin and destination of the air inside the cavity, natural/mechanical/fan supported ventilation and night cooling/venting. The dynamics of air movement in the cavity of double transparent façade with natural supported ventilation is based on natural convection especially on micro pressure caused by the gradient of temperature inside the cavity. In the summer night cavity is used for night pre-cooling. Indoor façade is open so hot air from the building could flowthrough the cavity out through the openings in the outdoor façade. Gradient of temperature causes hot air to rise up and cool air replaces that. Cool night air accumulates in the building structure and reduces the need for mechanical day
Název v anglickém jazyce
Natural Ventilation of the Double Transparent Facade Cavity
Popis výsledku anglicky
The modelling and simulation of the double façade transparent cavity is a complicated task. There are a lot of different elements which have influence over the function of the cavity. One important task is how the double façade transparent cavity is participated on the HVAC strategy. There is origin and destination of the air inside the cavity, natural/mechanical/fan supported ventilation and night cooling/venting. The dynamics of air movement in the cavity of double transparent façade with natural supported ventilation is based on natural convection especially on micro pressure caused by the gradient of temperature inside the cavity. In the summer night cavity is used for night pre-cooling. Indoor façade is open so hot air from the building could flowthrough the cavity out through the openings in the outdoor façade. Gradient of temperature causes hot air to rise up and cool air replaces that. Cool night air accumulates in the building structure and reduces the need for mechanical day
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
INDOOR ENVIRONMENT AND ENERGY PERFORMANCE OF HVAC-R SYSTEMS IN BUILDINGS
ISBN
978-80-89216-59-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
151-158
Název nakladatele
SSTP - Slovenská společnost pro techniku prostředí
Místo vydání
NITRA
Místo konání akce
Štrbské Pleso
Datum konání akce
1. 12. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—