Use of Natural Ventilation in Double Transparent Facades During Extreme Season Boundary Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00316820" target="_blank" >RIV/68407700:21110/17:00316820 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of Natural Ventilation in Double Transparent Facades During Extreme Season Boundary Conditions
Popis výsledku v původním jazyce
The primary advantage of double transparent façades is their ability to naturally ventilate multi-storey buildings. The use of these façades influences the thermal comfort inside a building. This study examines the difference between single and double transparent façades and whether the later has a positive impact on the thermal comfort. A CFD (Computational Fluid Dynamics) simplified model of an office room in 25th floor with a glass façade orientated to the south shows a positive influence on thermal comfort when a double façade is used. Comparing variants are with the highest dry-bulb temperature, the lowest dry-bulb temperature and the highest wind speed. Main comparing values inside the office are air temperature, airflow velocity, PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied).
Název v anglickém jazyce
Use of Natural Ventilation in Double Transparent Facades During Extreme Season Boundary Conditions
Popis výsledku anglicky
The primary advantage of double transparent façades is their ability to naturally ventilate multi-storey buildings. The use of these façades influences the thermal comfort inside a building. This study examines the difference between single and double transparent façades and whether the later has a positive impact on the thermal comfort. A CFD (Computational Fluid Dynamics) simplified model of an office room in 25th floor with a glass façade orientated to the south shows a positive influence on thermal comfort when a double façade is used. Comparing variants are with the highest dry-bulb temperature, the lowest dry-bulb temperature and the highest wind speed. Main comparing values inside the office are air temperature, airflow velocity, PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Recenzovaný sborník Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky 2017
ISBN
978-80-87952-22-1
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
Akademické sdružení MAGNANIMITAS
Místo vydání
Hradec Králové
Místo konání akce
Praha
Datum konání akce
18. 12. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—