Computational simulation of hygrothermal performance of hollow brick-based building envelopes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00218235" target="_blank" >RIV/68407700:21110/14:00218235 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computational simulation of hygrothermal performance of hollow brick-based building envelopes
Popis výsledku v původním jazyce
Computational analysis of hygrothermal performance of several types of hollow-brick based building envelopes is presented, aimed at the optimal hygric properties of hollow brick and exterior plaster. In the simulations, Künzel?s mathematical model of coupled heat and moisture transport is used. Dynamic climatic data in a form of Test Reference Year for Prague are utilized as boundary conditions. The computational results show that for a suitable hygrothermal performance of the analyzed envelopes the keyfactor is the hygric properties of the exterior plaster, whose value of moisture diffusivity has to be reduced to at least 1 10-10 m2/s, e.g. using hydrophobic agents. In that case, moisture content can be held under the hygroscopic threshold for almostthe whole reference year, which ensures the elimination of the presence of liquid moisture inside the envelope..
Název v anglickém jazyce
Computational simulation of hygrothermal performance of hollow brick-based building envelopes
Popis výsledku anglicky
Computational analysis of hygrothermal performance of several types of hollow-brick based building envelopes is presented, aimed at the optimal hygric properties of hollow brick and exterior plaster. In the simulations, Künzel?s mathematical model of coupled heat and moisture transport is used. Dynamic climatic data in a form of Test Reference Year for Prague are utilized as boundary conditions. The computational results show that for a suitable hygrothermal performance of the analyzed envelopes the keyfactor is the hygric properties of the exterior plaster, whose value of moisture diffusivity has to be reduced to at least 1 10-10 m2/s, e.g. using hydrophobic agents. In that case, moisture content can be held under the hygroscopic threshold for almostthe whole reference year, which ensures the elimination of the presence of liquid moisture inside the envelope..
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI3%2F085" target="_blank" >FR-TI3/085: Energeticky úsporné cihlové budovy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10th Nordic Symposium on Building Physics
ISBN
978-91-88722-53-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
223-230
Název nakladatele
Lund University
Místo vydání
Lund
Místo konání akce
Lund
Datum konání akce
15. 6. 2014