Hygrothermal analysis of surface layers of historical masonry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00316223" target="_blank" >RIV/68407700:21110/17:00316223 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.5012417" target="_blank" >http://dx.doi.org/10.1063/1.5012417</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5012417" target="_blank" >10.1063/1.5012417</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygrothermal analysis of surface layers of historical masonry
Popis výsledku v původním jazyce
The paper deals with the hygrothermal analysis of surface layers of historical masonry. Solid brick provided with a traditional and two modified lime-based plasters is studied. The heat and moisture transport in the envelope is induced by an exposure of the wall from the exterior side to dynamic climatic conditions of Olomouc, Czech Republic. The transport processes are described using diffusion type of mathematical model based on experimentally determined material properties. The computational results indicate that hygric transport and accumulation properties of exterior plasters affect the hygrothermal performance of the underlying solid brick in a very significant way, being able to regulate the amount of transported moisture. The modified lime plasters are not found generally superior to the traditional lime plasters in that respect. Therefore, their suitability for historical masonry should be assessed case by case, with a particular attention to the climatic conditions and to the properties of the load bearing structure.
Název v anglickém jazyce
Hygrothermal analysis of surface layers of historical masonry
Popis výsledku anglicky
The paper deals with the hygrothermal analysis of surface layers of historical masonry. Solid brick provided with a traditional and two modified lime-based plasters is studied. The heat and moisture transport in the envelope is induced by an exposure of the wall from the exterior side to dynamic climatic conditions of Olomouc, Czech Republic. The transport processes are described using diffusion type of mathematical model based on experimentally determined material properties. The computational results indicate that hygric transport and accumulation properties of exterior plasters affect the hygrothermal performance of the underlying solid brick in a very significant way, being able to regulate the amount of transported moisture. The modified lime plasters are not found generally superior to the traditional lime plasters in that respect. Therefore, their suitability for historical masonry should be assessed case by case, with a particular attention to the climatic conditions and to the properties of the load bearing structure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
60101 - History (history of science and technology to be 6.3, history of specific sciences to be under the respective headings)
Návaznosti výsledku
Projekt
<a href="/cs/project/DG16P02H046" target="_blank" >DG16P02H046: Vnitřní zateplovací systémy pro oblast architektonického dědictví</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Conference of Computational Methods in Sciences and Engineering 2017
ISBN
978-0-7354-1596-6
ISSN
—
e-ISSN
1551-7616
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
AIP Conference Proceedings
Místo vydání
New York
Místo konání akce
Thessaloniki
Datum konání akce
21. 4. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000419835900126