Changes in Energy and Temperature in the Ground Mass with Horizontal Heat Exchangers - The Energy Source for Heat Pumps
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00226750" target="_blank" >RIV/68407700:21110/15:00226750 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41310/15:67010
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.enbuild.2015.01.052" target="_blank" >http://dx.doi.org/10.1016/j.enbuild.2015.01.052</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.enbuild.2015.01.052" target="_blank" >10.1016/j.enbuild.2015.01.052</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Changes in Energy and Temperature in the Ground Mass with Horizontal Heat Exchangers - The Energy Source for Heat Pumps
Popis výsledku v původním jazyce
This article addresses soil temperature analysis, heat flows and energy transferred from the soil massif via a linear horizontal heat exchanger and horizontal heat exchanger of Slinky type. Heat exchangers are used as low-potential sources of thermal energy for heat pumps. Both exchangers were compared in terms of their influence on the soil massif temperature in the exchanger area, and on the exchanger power output. The exchangers were evaluated in the heating periods of 2011 - 2012, 2012 - 2013 and inthe exchanger stagnation period of 2011. The linear heat exchanger seems to be more suitable as a low-potential power supply for heat pumps. The average temperatures of the soil massif in the exchanger areas were positive in both heating periods and thetemperature was higher at the linear exchanger. The temperatures of the heat-transfer fluid exiting the exchangers were positive and the linear exchanger temperature was higher. The temperatures of the heat-transfer fluid entering the ex
Název v anglickém jazyce
Changes in Energy and Temperature in the Ground Mass with Horizontal Heat Exchangers - The Energy Source for Heat Pumps
Popis výsledku anglicky
This article addresses soil temperature analysis, heat flows and energy transferred from the soil massif via a linear horizontal heat exchanger and horizontal heat exchanger of Slinky type. Heat exchangers are used as low-potential sources of thermal energy for heat pumps. Both exchangers were compared in terms of their influence on the soil massif temperature in the exchanger area, and on the exchanger power output. The exchangers were evaluated in the heating periods of 2011 - 2012, 2012 - 2013 and inthe exchanger stagnation period of 2011. The linear heat exchanger seems to be more suitable as a low-potential power supply for heat pumps. The average temperatures of the soil massif in the exchanger areas were positive in both heating periods and thetemperature was higher at the linear exchanger. The temperatures of the heat-transfer fluid exiting the exchangers were positive and the linear exchanger temperature was higher. The temperatures of the heat-transfer fluid entering the ex
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energy and Buildings
ISSN
0378-7788
e-ISSN
—
Svazek periodika
92
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
107-115
Kód UT WoS článku
000351786900010
EID výsledku v databázi Scopus
2-s2.0-84923069727