Návrhové parametry a výstupy modelové studie tangenciálního spadiště s vysokým spádem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00241403" target="_blank" >RIV/68407700:21110/15:00241403 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Návrhové parametry a výstupy modelové studie tangenciálního spadiště s vysokým spádem
Popis výsledku v původním jazyce
The presented study is focused, similarly to previous work of the authors, on theoretical consideration and experimental work on the drop shafts with high hydraulic drop. Within the planning of new vertical drop shaft in Prague catchment the authors present latest results and findings at circular drop shaft with tangential vortex inlet. The results show that stable vortex structure with air core along the whole depth of the drop shaft can be created over the full range of flow conditions. This has a positive effect on energy attenuation using vortex structure and wall friction, and simultaneously accompanied with low water aeration. The mentioned positive effects enable to reduce the length of attenuation chamber and improve the flow conditions in outlet sewer section. Next to the study presents non-traditional design of foul sewage bypass including bottom opening structure
Název v anglickém jazyce
Hydraulic modelling of sewer dropshaft with tangential inlet structure
Popis výsledku anglicky
The presented study is focused, similarly to previous work of the authors, on theoretical consideration and experimental work on the drop shafts with high hydraulic drop. Within the planning of new vertical drop shaft in Prague catchment the authors present latest results and findings at circular drop shaft with tangential vortex inlet. The results show that stable vortex structure with air core along the whole depth of the drop shaft can be created over the full range of flow conditions. This has a positive effect on energy attenuation using vortex structure and wall friction, and simultaneously accompanied with low water aeration. The mentioned positive effects enable to reduce the length of attenuation chamber and improve the flow conditions in outlet sewer section. Next to the study presents non-traditional design of foul sewage bypass including bottom opening structure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Městské vody 2015 - Sborník přednášek konference s mezinárodní účastí
ISBN
978-80-86020-81-5
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
63-70
Název nakladatele
ARDEC s.r.o.
Místo vydání
Brno
Místo konání akce
Velké Bílovice
Datum konání akce
1. 10. 2015
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—