Spiral flow and pressure fluctuations in high shaft spillways
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00312304" target="_blank" >RIV/68407700:21110/17:00312304 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.barajguvenligi.org/publication/518/spiral-flow-and-pressure-fluctuations-in-high-shaft-spillways" target="_blank" >http://www.barajguvenligi.org/publication/518/spiral-flow-and-pressure-fluctuations-in-high-shaft-spillways</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spiral flow and pressure fluctuations in high shaft spillways
Popis výsledku v původním jazyce
The paper is focused on improvement of hydraulic conditions in high shaft spillways due to spiral flow enforcement. It presents results from 1:20 scale physical model of complete structure of high circular shaft spillway equipped with different arrangements of pro-vortex structures at the circular intake section (shape, numbers). The effect of spiral flow in the shaft is commented from the pressure fluctuations, overall capacity and stability of the flow conditions point of view. Pressure fluctuations were measured in the shaft and along the outlet tunnel with high frequency probes. The influence of the shape of the bend between the shaft and the outlet tunnel together with flow regime in the outlet tunnel on the pressure fluctuations is evaluated. Comparison with axial flow without pro-vortex vanes is also provided in the paper.
Název v anglickém jazyce
Spiral flow and pressure fluctuations in high shaft spillways
Popis výsledku anglicky
The paper is focused on improvement of hydraulic conditions in high shaft spillways due to spiral flow enforcement. It presents results from 1:20 scale physical model of complete structure of high circular shaft spillway equipped with different arrangements of pro-vortex structures at the circular intake section (shape, numbers). The effect of spiral flow in the shaft is commented from the pressure fluctuations, overall capacity and stability of the flow conditions point of view. Pressure fluctuations were measured in the shaft and along the outlet tunnel with high frequency probes. The influence of the shape of the bend between the shaft and the outlet tunnel together with flow regime in the outlet tunnel on the pressure fluctuations is evaluated. Comparison with axial flow without pro-vortex vanes is also provided in the paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102014056" target="_blank" >VG20102014056: Zvýšení spolehlivosti manipulačních objektů na vodních dílech pro překonání krizových situací za živelných pohrom a provozních havárií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings 85th ICOLD Annual Meeting International Symposium
ISBN
978-80-906662-1-4
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
GUARANT International spol. s r.o.
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
5. 7. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—