Influence of artificial aging on structural adhesive connections for façade applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F18%3A00320141" target="_blank" >RIV/68407700:21110/18:00320141 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21610/18:00320141
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0143749618300551" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0143749618300551</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijadhadh.2018.02.022" target="_blank" >10.1016/j.ijadhadh.2018.02.022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of artificial aging on structural adhesive connections for façade applications
Popis výsledku v původním jazyce
Contemporary architecture often requires adhesive connections as a bonding method of façade cladding elements to the supporting substructure, due to their visually smooth surface without the interruption by bolts. Low strength, elastic and durable silicone sealants have been used in façades for a long period of time, but there is a lack of information about semi-flexible and semi-rigid adhesives with higher strengths. The building façade is a very specific application for adhesive connections due to the requirements for durability, strict geometrical imperfections and joining of unconventional materials often used in the façade design. The presented paper is focused on experimental analyses of structural adhesive joints exposed to laboratory aging conditions. Due to the absence of a particular code intended for structural adhesive joints in façades, two artificial aging procedures were chosen – ETAG 002 and ISO 9142 - E4 Procedure (Exposure to neutral salt spray and elevated temperature and humidity). The joints are bonded by two different adhesives, Silane Terminated Polymer (STP), and a two-part acrylate adhesive. The joints are composed of blank aluminum with a smooth and roughened surface, anodized aluminum and galvanized steel with a smooth and roughened surface. Mechanical behavior and failure modes of a reference set of specimens are compared with the results of two specimen sets exposed to aging. The degrading effect of demineralized water immersion was more crucial for the STP adhesive than the salt spray test. On the contrary, the effect of the salt spray test was more serious for the acrylate adhesive than immersion in water. The experimental study showed that the degrading effect of a particular aging procedure can be more harmful to one adhesive than the others in dependence on the time of exposure.
Název v anglickém jazyce
Influence of artificial aging on structural adhesive connections for façade applications
Popis výsledku anglicky
Contemporary architecture often requires adhesive connections as a bonding method of façade cladding elements to the supporting substructure, due to their visually smooth surface without the interruption by bolts. Low strength, elastic and durable silicone sealants have been used in façades for a long period of time, but there is a lack of information about semi-flexible and semi-rigid adhesives with higher strengths. The building façade is a very specific application for adhesive connections due to the requirements for durability, strict geometrical imperfections and joining of unconventional materials often used in the façade design. The presented paper is focused on experimental analyses of structural adhesive joints exposed to laboratory aging conditions. Due to the absence of a particular code intended for structural adhesive joints in façades, two artificial aging procedures were chosen – ETAG 002 and ISO 9142 - E4 Procedure (Exposure to neutral salt spray and elevated temperature and humidity). The joints are bonded by two different adhesives, Silane Terminated Polymer (STP), and a two-part acrylate adhesive. The joints are composed of blank aluminum with a smooth and roughened surface, anodized aluminum and galvanized steel with a smooth and roughened surface. Mechanical behavior and failure modes of a reference set of specimens are compared with the results of two specimen sets exposed to aging. The degrading effect of demineralized water immersion was more crucial for the STP adhesive than the salt spray test. On the contrary, the effect of the salt spray test was more serious for the acrylate adhesive than immersion in water. The experimental study showed that the degrading effect of a particular aging procedure can be more harmful to one adhesive than the others in dependence on the time of exposure.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-17461S" target="_blank" >GA16-17461S: Dynamické materiálové vlastnosti viskoelastických fólií používaných ve vrstvených sklech</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Adhesion and Adhesives
ISSN
0143-7496
e-ISSN
1879-0127
Svazek periodika
83
Číslo periodika v rámci svazku
June
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
168-177
Kód UT WoS článku
000440266300021
EID výsledku v databázi Scopus
2-s2.0-85043322746