The staircase is an integral part of most buildings. It is subject to the same technological principles and constraints as for other building structures. This design must meet basic technical requirements, including stairway safety. The requirements for selected geometric parameters of stair steps are defined in Czech technical standards and regulations. Generally, the requirements of these regulations are summarized as follows: "All the stairs to the walking line in one flight must have the same height and width and must be horizontal, without inclination in the transverse or longitudinal direction." This provision prescribes mainly design requirements of stairs, while the requirements for as-built stairs are not taken into account. This is evidenced by the fact that in the Czech technical regulations and standards the geometrical accuracy of the as-built stair steps is not specified. Deviations from the geometrical accuracy of stair steps are technologically inevitable.
Název v anglickém jazyce
Staircase - Dimensions of Stair Steps and their Deviations of Geometrical Accuracy
Popis výsledku anglicky
The staircase is an integral part of most buildings. It is subject to the same technological principles and constraints as for other building structures. This design must meet basic technical requirements, including stairway safety. The requirements for selected geometric parameters of stair steps are defined in Czech technical standards and regulations. Generally, the requirements of these regulations are summarized as follows: "All the stairs to the walking line in one flight must have the same height and width and must be horizontal, without inclination in the transverse or longitudinal direction." This provision prescribes mainly design requirements of stairs, while the requirements for as-built stairs are not taken into account. This is evidenced by the fact that in the Czech technical regulations and standards the geometrical accuracy of the as-built stair steps is not specified. Deviations from the geometrical accuracy of stair steps are technologically inevitable.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-899X
e-ISSN
1757-899X
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IOP Publishing Ltd.
Místo vydání
Bristol
Místo konání akce
Praha
Datum konání akce
18. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000465811800012