Young’s Modulus of Illite-Quartz Samples in the Temperature Interval of 25 °C – 800 °C
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F20%3A00342926" target="_blank" >RIV/68407700:21110/20:00342926 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1063/5.0025868" target="_blank" >https://doi.org/10.1063/5.0025868</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0025868" target="_blank" >10.1063/5.0025868</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Young’s Modulus of Illite-Quartz Samples in the Temperature Interval of 25 °C – 800 °C
Popis výsledku v původním jazyce
The quartz grains increase their volume and generate stress in their close surroundings in the temperature interval of the alfa -> beta transformation of quartz. Since many quartz grains have circumferential microcracks around them, the stress has a healing effect. This leads to the rapid increase of Young’s modulus of fired samples. The samples studied in this paper are prepared from illite and quartz sand with the content of 10, 20, 30, 40, and 50 mass% of quartz sand. Young’s modulus of illite-quartz samples, which are preheated up to 1100 °C, is measured by dynamical thermomechanical analysis, which is based on the impulse excitation technique. Measurements are carried out during heating and cooling stage of firing in the temperature interval from 25 °C to 800 °C.
Název v anglickém jazyce
Young’s Modulus of Illite-Quartz Samples in the Temperature Interval of 25 °C – 800 °C
Popis výsledku anglicky
The quartz grains increase their volume and generate stress in their close surroundings in the temperature interval of the alfa -> beta transformation of quartz. Since many quartz grains have circumferential microcracks around them, the stress has a healing effect. This leads to the rapid increase of Young’s modulus of fired samples. The samples studied in this paper are prepared from illite and quartz sand with the content of 10, 20, 30, 40, and 50 mass% of quartz sand. Young’s modulus of illite-quartz samples, which are preheated up to 1100 °C, is measured by dynamical thermomechanical analysis, which is based on the impulse excitation technique. Measurements are carried out during heating and cooling stage of firing in the temperature interval from 25 °C to 800 °C.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20504 - Ceramics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings 2275
ISBN
978-0-7354-4005-0
ISSN
—
e-ISSN
1551-7616
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
AIP Publishing, APL, the American Institute of Physics
Místo vydání
Melville, NY
Místo konání akce
Eger
Datum konání akce
2. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce