Popis výsledku v původním jazyce
The steam generator in nuclear power plant is designed in such a way that it physically separates the primary circuit that contains radioactive substances from the secondary circuit, which no longer contains them. The steam generator is a category 1 device, and therefore, it is required to minimize its breakdowns. Therefore, a device care strategy is chosen that ensures high reliability, i.e. minimizes the occurrence of failures and does not tolerate functional failures between established maintenance cycles. For economic reasons, the preventive maintenance program is controlled by the maintenance of the items that contribute most to the failure of the steam generator.
Název v anglickém jazyce
METHODOLOGY OF COMPILING A STEAM GENERATOR MAINTENANCE PLAN
Popis výsledku anglicky
The steam generator in nuclear power plant is designed in such a way that it physically separates the primary circuit that contains radioactive substances from the secondary circuit, which no longer contains them. The steam generator is a category 1 device, and therefore, it is required to minimize its breakdowns. Therefore, a device care strategy is chosen that ensures high reliability, i.e. minimizes the occurrence of failures and does not tolerate functional failures between established maintenance cycles. For economic reasons, the preventive maintenance program is controlled by the maintenance of the items that contribute most to the failure of the steam generator.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník semináře doktorandů katedry ocelových a dřevěných konstrukcí 2023
ISBN
978-80-01-07172-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
28-31
Název nakladatele
katedra ocelových a dřevěných konstrukcí
Místo vydání
Praha
Místo konání akce
Fakulta stavební
Datum konání akce
13. 2. 2023
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—