Methodology of Compiling A Steam Generator Maintenance Plan
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F23%3A00368314" target="_blank" >RIV/68407700:21110/23:00368314 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/23:00368314
Výsledek na webu
<a href="http://dx.doi.org/10.3850/978-981-18-8071-1_P069-cd" target="_blank" >http://dx.doi.org/10.3850/978-981-18-8071-1_P069-cd</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3850/978-981-18-8071-1_P069-cd" target="_blank" >10.3850/978-981-18-8071-1_P069-cd</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methodology of Compiling A Steam Generator Maintenance Plan
Popis výsledku v původním jazyce
The steam generator in nuclear power plant is designed in such a way that it physically separates the primary circuit that contains radioactive substances from the secondary circuit, which no longer contains them. The steam generator is a category 1 device, and therefore it is required to minimize breakdowns. Therefore, a device care strategy is chosen that ensures high reliability, i.e. minimizes the occurrence of failures and does not tolerate functional failures between established maintenance cycles. For economic reasons, the preventive maintenance program is controlled by the maintenance of the items that contribute most to the failure of the steam generator. In the paper, we show procedure by which we prepared steam generator maintenance plan for proactive preventive maintenance.
Název v anglickém jazyce
Methodology of Compiling A Steam Generator Maintenance Plan
Popis výsledku anglicky
The steam generator in nuclear power plant is designed in such a way that it physically separates the primary circuit that contains radioactive substances from the secondary circuit, which no longer contains them. The steam generator is a category 1 device, and therefore it is required to minimize breakdowns. Therefore, a device care strategy is chosen that ensures high reliability, i.e. minimizes the occurrence of failures and does not tolerate functional failures between established maintenance cycles. For economic reasons, the preventive maintenance program is controlled by the maintenance of the items that contribute most to the failure of the steam generator. In the paper, we show procedure by which we prepared steam generator maintenance plan for proactive preventive maintenance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 33rd European Safety and Reliability Conference (ESREL 2023)
ISBN
978-981-18-8071-1
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
1477-1484
Název nakladatele
Research Publishing Services
Místo vydání
Singapore
Místo konání akce
Southampton
Datum konání akce
3. 9. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce