Posouzení odlehčovacích komor v Jindřichově Hradci metodou sledování částic v CFD
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F25%3A00385115" target="_blank" >RIV/68407700:21110/25:00385115 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Posouzení odlehčovacích komor v Jindřichově Hradci metodou sledování částic v CFD
Popis výsledku v původním jazyce
This study presents a CFD-based particle tracking analysis of six combined sewer overflow (CSO) chambers in the city of Jindřichův Hradec (Czech Republic) to evaluate their pollutant retention efficiency. A Lagrangian multiphase approach was used to simulate the transport of solid fractions under various flow conditions. Each overflow event was modeled to determine the distribution of pollutant particles between wastewater treatment plant outflow, internal retention, and discharge to the Vajgar pond. The simulation results were combined with annual overflow volumes and pollutant concentration data to estimate the total annual load of suspended solids (TSS) and chemical oxygen demand (COD) entering the pond. The findings revealed significant differences in performance among the CSOs. Two chambers were responsible for nearly two tonnes of annual pollutant load, highlighting the need for targeted retrofitting of specific structures. The proposed method offers a detailed and site-specific evaluation framework compliant with EU wastewater legislation.
Název v anglickém jazyce
Assessment of relief chambers in Jindřichův Hradec using the particle tracking method in CFD
Popis výsledku anglicky
This study presents a CFD-based particle tracking analysis of six combined sewer overflow (CSO) chambers in the city of Jindřichův Hradec (Czech Republic) to evaluate their pollutant retention efficiency. A Lagrangian multiphase approach was used to simulate the transport of solid fractions under various flow conditions. Each overflow event was modeled to determine the distribution of pollutant particles between wastewater treatment plant outflow, internal retention, and discharge to the Vajgar pond. The simulation results were combined with annual overflow volumes and pollutant concentration data to estimate the total annual load of suspended solids (TSS) and chemical oxygen demand (COD) entering the pond. The findings revealed significant differences in performance among the CSOs. Two chambers were responsible for nearly two tonnes of annual pollutant load, highlighting the need for targeted retrofitting of specific structures. The proposed method offers a detailed and site-specific evaluation framework compliant with EU wastewater legislation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20701 - Environmental and geological engineering, geotechnics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník příspěvků odborné konference SVK STOKA 2025
ISBN
978-80-01-07434-3
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
43-51
Název nakladatele
katedra vodního hospodářství obcí
Místo vydání
Praha
Místo konání akce
Mariánská
Datum konání akce
23. 6. 2025
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—