Optimizing Separation Efficiency in CSOs using CFD
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F25%3A00385116" target="_blank" >RIV/68407700:21110/25:00385116 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimizing Separation Efficiency in CSOs using CFD
Popis výsledku v původním jazyce
Combined sewer overflows (CSOs) pose a major issue in urban drainage, especially during intense rainfall when system capacity is exceeded. Efficient separation of suspended solids in CSO structures is crucial to limit pollution entering receiving waters. This study explores how design parameters affect separation efficiency in a pipe-type CSO using computational fluid dynamics. The CSO was modeled using a VOF model combined with Lagrangian particle tracking representing pollution. Design variables such object length and overflow slot geometry shape were evaluated under varying flow rates. The results confirm that longer chambers significantly improve separation efficiency due to increased residence time. Changes in slot geometry, however, had only a limited and inconsistent impact, suggesting a secondary role influenced by specific flow conditions.
Název v anglickém jazyce
Optimizing Separation Efficiency in CSOs using CFD
Popis výsledku anglicky
Combined sewer overflows (CSOs) pose a major issue in urban drainage, especially during intense rainfall when system capacity is exceeded. Efficient separation of suspended solids in CSO structures is crucial to limit pollution entering receiving waters. This study explores how design parameters affect separation efficiency in a pipe-type CSO using computational fluid dynamics. The CSO was modeled using a VOF model combined with Lagrangian particle tracking representing pollution. Design variables such object length and overflow slot geometry shape were evaluated under varying flow rates. The results confirm that longer chambers significantly improve separation efficiency due to increased residence time. Changes in slot geometry, however, had only a limited and inconsistent impact, suggesting a secondary role influenced by specific flow conditions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20701 - Environmental and geological engineering, geotechnics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník příspěvků odborné konference SVK STOKA 2025
ISBN
978-80-01-07434-3
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
60-68
Název nakladatele
katedra vodního hospodářství obcí
Místo vydání
Praha
Místo konání akce
Mariánská
Datum konání akce
23. 6. 2025
Typ akce podle státní příslušnosti
CST - Celostátní akce