In-situ measurement of dynamics of pump-pipeline system transporting sewage sludge. Part II. Change in operating characteristics of a pump during sewage sludge pumping
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F25%3A00385663" target="_blank" >RIV/68407700:21110/25:00385663 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/25:00385663
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In-situ measurement of dynamics of pump-pipeline system transporting sewage sludge. Part II. Change in operating characteristics of a pump during sewage sludge pumping
Popis výsledku v původním jazyce
This study investigates the issue of sewage sludge pumping, with a focus on methods for recalculating the performance parameters of a specific hydrodynamic sludge pump from values relevant to clean water pumping to those applicable to sewage sludge pumping. The pump under assessment is the Flygt NT 3301 HT - 458, featuring a nominal power of 55 kW, a rated speed of 1475 rpm, and a specific speed of 34.4 rpm. Performance parameters were measured during the pumping of sewage sludge with a dry solids content of 5.2%. The experimentally obtained performance parameters and pump performance curves for sludge pumping were compared to predicted performance curves recalculated from clean water to 5.2% sewage sludge. Differences between the experimental and predicted values are analysed, and the suitability of the applied recalculation methods is assessed. The study concludes with recommendations for optimizing the performance parameters of hydrodynamic sludge pumps in wastewater treatment plants.
Název v anglickém jazyce
In-situ measurement of dynamics of pump-pipeline system transporting sewage sludge. Part II. Change in operating characteristics of a pump during sewage sludge pumping
Popis výsledku anglicky
This study investigates the issue of sewage sludge pumping, with a focus on methods for recalculating the performance parameters of a specific hydrodynamic sludge pump from values relevant to clean water pumping to those applicable to sewage sludge pumping. The pump under assessment is the Flygt NT 3301 HT - 458, featuring a nominal power of 55 kW, a rated speed of 1475 rpm, and a specific speed of 34.4 rpm. Performance parameters were measured during the pumping of sewage sludge with a dry solids content of 5.2%. The experimentally obtained performance parameters and pump performance curves for sludge pumping were compared to predicted performance curves recalculated from clean water to 5.2% sewage sludge. Differences between the experimental and predicted values are analysed, and the suitability of the applied recalculation methods is assessed. The study concludes with recommendations for optimizing the performance parameters of hydrodynamic sludge pumps in wastewater treatment plants.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 22nd International Conference on HYDROTRANSPORT
ISBN
978-80-01-07404-6
ISSN
—
e-ISSN
—
Počet stran výsledku
14
Strana od-do
198-211
Název nakladatele
CESKE VYSOKE UCENI TECHNICKE V PRAZE
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
27. 5. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—