Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F01%3A04068253" target="_blank" >RIV/68407700:21220/01:04068253 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter
Popis výsledku v původním jazyce
This study was concentrated on the assessment of the basic physical properties of polymer gel dosimeter evaluated by NMR. BANG-2 type polymer gel was prepared. The dosimeters were irradiated by 60Co gamma photons and by 4 MV, 6 MV and 18 MV X ray photonsby doses in the range of 0-50 Gy. Multi-echo CPMG sequence was used for the evaluation of T2-relaxation times in irradiated gel dosimeters. The dependence of 1/T2 response of dosimeters was studied on following factors: absorbed dose, energy of applied radiation, temperature during NMR evaluation, time since irradiation to NMR evaluation and strength of the magnetic field. An exponential dependence of 1/T2 response on absorbed dose in the range of 0-50 Gy was observed, in the range 0-10 Gy the data could be fitted by linear function. There was described the dependence of 1/T2 response on: energy, strength of magnetic field and time from irradiation of the dosimeters to NMR evaluation. Increase of gel dosimeter 1/T2 response with the d.
Název v anglickém jazyce
Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter
Popis výsledku anglicky
This study was concentrated on the assessment of the basic physical properties of polymer gel dosimeter evaluated by NMR. BANG-2 type polymer gel was prepared. The dosimeters were irradiated by 60Co gamma photons and by 4 MV, 6 MV and 18 MV X ray photonsby doses in the range of 0-50 Gy. Multi-echo CPMG sequence was used for the evaluation of T2-relaxation times in irradiated gel dosimeters. The dependence of 1/T2 response of dosimeters was studied on following factors: absorbed dose, energy of applied radiation, temperature during NMR evaluation, time since irradiation to NMR evaluation and strength of the magnetic field. An exponential dependence of 1/T2 response on absorbed dose in the range of 0-50 Gy was observed, in the range 0-10 Gy the data could be fitted by linear function. There was described the dependence of 1/T2 response on: energy, strength of magnetic field and time from irradiation of the dosimeters to NMR evaluation. Increase of gel dosimeter 1/T2 response with the d.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Phys. Chem
ISSN
0969-806X
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
255-258
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—