Electrochemical Measurement of Impeller Speed for Off-Bottom Suspension
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F03%3A02093051" target="_blank" >RIV/68407700:21220/03:02093051 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Measurement of Impeller Speed for Off-Bottom Suspension
Popis výsledku v původním jazyce
State of just off-bottom particle suspension was often determined visually based on observation of the particles sediment at the bottom by classical Zwietering's concept. Accuracy of visual observation of particle layer sediment on the vessel bottom depends on subjective experience of experimenter. This visual method is very simple but it is often difficult to apply or inapplicable e.g. for badly transparent, non-transparent or highly concentrated suspensions. This disadvantage is possible to remove bya new application of the electrochemical method for observation of particle layer sediment on the vessel bottom and for identifying the state of just off-bottom particle suspension. The results of signal analysis and comparison with visual method illustrate very well usability of the electrochemical method for observation of particle layer sediment behaviour on the vessel bottom and for identification of state of just off-bottom particle suspension. These conclusions were verified by vi.
Název v anglickém jazyce
Electrochemical Measurement of Impeller Speed for Off-Bottom Suspension
Popis výsledku anglicky
State of just off-bottom particle suspension was often determined visually based on observation of the particles sediment at the bottom by classical Zwietering's concept. Accuracy of visual observation of particle layer sediment on the vessel bottom depends on subjective experience of experimenter. This visual method is very simple but it is often difficult to apply or inapplicable e.g. for badly transparent, non-transparent or highly concentrated suspensions. This disadvantage is possible to remove bya new application of the electrochemical method for observation of particle layer sediment on the vessel bottom and for identifying the state of just off-bottom particle suspension. The results of signal analysis and comparison with visual method illustrate very well usability of the electrochemical method for observation of particle layer sediment behaviour on the vessel bottom and for identification of state of just off-bottom particle suspension. These conclusions were verified by vi.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F02%2F0615" target="_blank" >GA101/02/0615: Míchání koncentrovaných suspenzí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 11th European Conference on Mixing
ISBN
3-931384-45-4
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
519-526
Název nakladatele
VDI - Gessellschaft Fahrzeug und Verkehrstechnik
Místo vydání
Düsseldorf
Místo konání akce
Bamberg
Datum konání akce
14. 10. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce