Aplikace elektrodifúzní diagnostiky na sledování průběhu suspendace
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F03%3A02093059" target="_blank" >RIV/68407700:21220/03:02093059 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Aplikace elektrodifúzní diagnostiky na sledování průběhu suspendace
Popis výsledku v původním jazyce
State of just off-bottom particle suspension was often determined visually based on observation of the particles sediment at the bottom by classical Zwietering's concept [1]. Accuracy of visual observation of particle layer sediment on the vessel bottomdepends on subjective experience of experimenter. This visual method is very simple but it is often difficult to apply or inapplicable e.g. for badly transparent, non-transparent or highly concentrated suspensions. This disadvantage is possible to removeby a new application of the electrochemical method for observation of particle layer sediment on the vessel bottom and for identifying the state of just off-bottom particle suspension. Similar concept of particle layer sediment observation was used by Mak et all but these authors used the Ultra-sonic Doppler Flowmeter (ultrasonic probe at the vessel bottom). Other direct and indirect methods for identification of just off-bottom particle suspension state were compared by Rieger and Dit.
Název v anglickém jazyce
Application of Electrochemical Measurement for Observation of Particle Suspension
Popis výsledku anglicky
State of just off-bottom particle suspension was often determined visually based on observation of the particles sediment at the bottom by classical Zwietering's concept [1]. Accuracy of visual observation of particle layer sediment on the vessel bottomdepends on subjective experience of experimenter. This visual method is very simple but it is often difficult to apply or inapplicable e.g. for badly transparent, non-transparent or highly concentrated suspensions. This disadvantage is possible to removeby a new application of the electrochemical method for observation of particle layer sediment on the vessel bottom and for identifying the state of just off-bottom particle suspension. Similar concept of particle layer sediment observation was used by Mak et all but these authors used the Ultra-sonic Doppler Flowmeter (ultrasonic probe at the vessel bottom). Other direct and indirect methods for identification of just off-bottom particle suspension state were compared by Rieger and Dit.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F02%2F0615" target="_blank" >GA101/02/0615: Míchání koncentrovaných suspenzí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
13. Celostátní konference "Míchání, stavba míchacích zařízení, ucpávky"
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
1-11
Název nakladatele
Česká společnost chemického inženýrství
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
8. 9. 2003
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—