Proudové charakteristiky za připojením end-to-side bypasu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F05%3A02113395" target="_blank" >RIV/68407700:21220/05:02113395 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow Investigation behind the End-to-Side Anastomosis
Popis výsledku v původním jazyce
The velocity field was measured by 2D PIV method. The flow field was measured in symmetry plane for steady conditions (Re=500, Re=1400). The bypass models were made from plexiglass with connection angles 20°, 30°, 45°, 60° a 90°. 60% solution of sodium-iodine (NaI) was used as a working fluid. Fluorescent particles were used as seeding particles. The camera was placed perpendicular to the laser sheet. Six areas were measured along the host artery (length of measured area was approximately 60mm). Connection of flow fields and other evaluation were carried out in the Matlab. The goal of this work was to describe the velocity field behind the distal end-to-side bypass junction in dependence on the connection angle both experimentally and numerically.
Název v anglickém jazyce
Flow Investigation behind the End-to-Side Anastomosis
Popis výsledku anglicky
The velocity field was measured by 2D PIV method. The flow field was measured in symmetry plane for steady conditions (Re=500, Re=1400). The bypass models were made from plexiglass with connection angles 20°, 30°, 45°, 60° a 90°. 60% solution of sodium-iodine (NaI) was used as a working fluid. Fluorescent particles were used as seeding particles. The camera was placed perpendicular to the laser sheet. Six areas were measured along the host artery (length of measured area was approximately 60mm). Connection of flow fields and other evaluation were carried out in the Matlab. The goal of this work was to describe the velocity field behind the distal end-to-side bypass junction in dependence on the connection angle both experimentally and numerically.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F05%2F0675" target="_blank" >GA101/05/0675: Teoretická a experimentální optimalizace cévních rekonstrukcí z hlediska hemodynamiky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The 16th International Symposium on Transport Phenomena
ISBN
80-86786-04-8
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
107-107
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
29. 8. 2005
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—