Název v původním jazyce
Optimization of the PWV Measurement in Arteries
Popis výsledku v původním jazyce
Measurements of the pulse wave velocity (PWV) in human arteries are important for two different reasons: an early diagnostics of atherosclerosis and identification of material properties of the vessel wall for numerical simulations. The PWV in blood vessels is not constant and classical methods of pressure wave shift between two points are not sufficient. We consider three methods: optical measurements of vessel wall displacement in several points by high speed camera, continual optical measurements ofvessel wall displacement by correlator Q-450 and measurements of flow rate and displacements by ultrasonic device. The first method can determine the PWV only between several points. The second method can show 3D reconstruction of displacements with verygood resolution. The ultrasound measurements need combination of Doppler ultrasound velocimetry and B-scan imagining. However, the common devices used in medicine do not have any data output. It causes bad resolution.
Název v anglickém jazyce
Optimization of the PWV Measurement in Arteries
Popis výsledku anglicky
Measurements of the pulse wave velocity (PWV) in human arteries are important for two different reasons: an early diagnostics of atherosclerosis and identification of material properties of the vessel wall for numerical simulations. The PWV in blood vessels is not constant and classical methods of pressure wave shift between two points are not sufficient. We consider three methods: optical measurements of vessel wall displacement in several points by high speed camera, continual optical measurements ofvessel wall displacement by correlator Q-450 and measurements of flow rate and displacements by ultrasonic device. The first method can determine the PWV only between several points. The second method can show 3D reconstruction of displacements with verygood resolution. The ultrasound measurements need combination of Doppler ultrasound velocimetry and B-scan imagining. However, the common devices used in medicine do not have any data output. It causes bad resolution.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F04%2F1181" target="_blank" >GA106/04/1181: Identifikace materiálových vlastností cévních stěn</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Summer Workshop of Applied Mechanics 2006
ISBN
80-01-03453-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
74-79
Název nakladatele
Fakulta strojní ČVUT
Místo vydání
Praha
Místo konání akce
FME CTU in Prague
Datum konání akce
6. 10. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—