Optické vyhodnocení rychlosti pulsní vlny
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F06%3A02121229" target="_blank" >RIV/68407700:21220/06:02121229 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/06:00047440
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optical Evaluation of the Pulse Wave Velocity
Popis výsledku v původním jazyce
The pulse wave velocity (PWV) in arteries is determined mainly by the elasticity of the vessel wall. Therefore it can be used as an indicator of diseased blood vessels in the cardiovascular medicine. In our laboratory, the elastic properties of the arterial tissue are determined from the PWV. One of the methods for measuring the PWV is an optical method. A high speed camera records the displacements of the vessel wall loaded by a pulsatile flow and the propagation of the equal displacement values is evaluated. However, the shape and elastic properties of the biological specimen vary along the axis of the tube; therefore the PWV is not constant. To detect the local changes of the PWV, high space and time resolution is needed. Therefore, the correlationof two camera records (the Q-450 system) is one of the promising possibilities for measuring the PWV in vitro
Název v anglickém jazyce
Optical Evaluation of the Pulse Wave Velocity
Popis výsledku anglicky
The pulse wave velocity (PWV) in arteries is determined mainly by the elasticity of the vessel wall. Therefore it can be used as an indicator of diseased blood vessels in the cardiovascular medicine. In our laboratory, the elastic properties of the arterial tissue are determined from the PWV. One of the methods for measuring the PWV is an optical method. A high speed camera records the displacements of the vessel wall loaded by a pulsatile flow and the propagation of the equal displacement values is evaluated. However, the shape and elastic properties of the biological specimen vary along the axis of the tube; therefore the PWV is not constant. To detect the local changes of the PWV, high space and time resolution is needed. Therefore, the correlationof two camera records (the Q-450 system) is one of the promising possibilities for measuring the PWV in vitro
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F04%2F1181" target="_blank" >GA106/04/1181: Identifikace materiálových vlastností cévních stěn</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
13th International User Meeting 2006
ISBN
3-00-019900-4
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Dantec Dynamics GmbH
Místo vydání
Ulm
Místo konání akce
Ulm
Datum konání akce
11. 10. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—