Autotuning založený na frekvenčně vyhodnocovaných indikátorech kvality regulačního pochodu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F08%3A02147763" target="_blank" >RIV/68407700:21220/08:02147763 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Frequency Analysis Based Quality Control Indicator Autotuning
Popis výsledku v původním jazyce
There exists a lot of modern controller algorithm, but the most used controller algorithm in praxis is still PI/PID algorithm. It is because industrial praxis prefers experimental tuning than model based tuning. The advantages of PI/PID controller are its relative simplicity and understanding of its function without necessity of deep control theory knowledge. The most used tuning rules are still Ziegler and Nichols rules (which was published in 1942), in some last years Aström and Hägglund method becomes popular. Both two methods have significant disadvantage - interrupted control function during new controller parameter finding. It means that disturbance are not eliminated in these moments. This is the reason for new PI/PID controller autotuning method development. The method is based on set of control quality indicators and it can find optimal controller parameters during control function of controller.
Název v anglickém jazyce
Frequency Analysis Based Quality Control Indicator Autotuning
Popis výsledku anglicky
There exists a lot of modern controller algorithm, but the most used controller algorithm in praxis is still PI/PID algorithm. It is because industrial praxis prefers experimental tuning than model based tuning. The advantages of PI/PID controller are its relative simplicity and understanding of its function without necessity of deep control theory knowledge. The most used tuning rules are still Ziegler and Nichols rules (which was published in 1942), in some last years Aström and Hägglund method becomes popular. Both two methods have significant disadvantage - interrupted control function during new controller parameter finding. It means that disturbance are not eliminated in these moments. This is the reason for new PI/PID controller autotuning method development. The method is based on set of control quality indicators and it can find optimal controller parameters during control function of controller.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F07%2F1667" target="_blank" >GA101/07/1667: Provozně zajištěná pokročilá regulace tepelně-energetických zařízení</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Workshop 2008
ISBN
978-80-01-04016-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
18. 2. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—