Heat transfer enhancement in a pipe, using a flow inverter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F09%3A00158946" target="_blank" >RIV/68407700:21220/09:00158946 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heat transfer enhancement in a pipe, using a flow inverter
Popis výsledku v původním jazyce
Flow inversion, transferring a liquid from the wall region towards the center of the pipe improves heat transfer in the laminar flow regime. Two original flow inverter designs were tested in a long pipe (3m in length) heated by condensing steam, using starch molasses as a working medium. Experiments carried out in the range of Reynolds number 4 - 60 and Graetz number 150 - 700 resulted in an increase of 20 - 35% in the heat transfer coefficient, accompanied by a 30-40% increase in the pressure drop. Theexperimental results confirm the numerical model prediction (within an extended Reynolds number range starting from Re=0.1). Thus an almost 40% increase in heat transfer can be expected at the optimal Graetz number in the range 50-100, using only one flow inverter located in the middle of a sufficiently long pipe.
Název v anglickém jazyce
Heat transfer enhancement in a pipe, using a flow inverter
Popis výsledku anglicky
Flow inversion, transferring a liquid from the wall region towards the center of the pipe improves heat transfer in the laminar flow regime. Two original flow inverter designs were tested in a long pipe (3m in length) heated by condensing steam, using starch molasses as a working medium. Experiments carried out in the range of Reynolds number 4 - 60 and Graetz number 150 - 700 resulted in an increase of 20 - 35% in the heat transfer coefficient, accompanied by a 30-40% increase in the pressure drop. Theexperimental results confirm the numerical model prediction (within an extended Reynolds number range starting from Re=0.1). Thus an almost 40% increase in heat transfer can be expected at the optimal Graetz number in the range 50-100, using only one flow inverter located in the middle of a sufficiently long pipe.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F06%2F0535" target="_blank" >GA101/06/0535: Tepelné zpracování biodegradovatelných látek</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heat Transfer Engineering
ISSN
0145-7632
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000265857600005
EID výsledku v databázi Scopus
—