Image Registration Procedure Used in Intrasubject Comparison of Pelvic Configuration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F09%3A00161422" target="_blank" >RIV/68407700:21220/09:00161422 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Image Registration Procedure Used in Intrasubject Comparison of Pelvic Configuration
Popis výsledku v původním jazyce
The objective of the study was to prove magnetic resonance imaging (MRI) as suitable instrument for exploring displacements within the bony pelvis induced by altered pelvic floor muscle characteristics. Repeated MRI of 14 females was performed. Coordinates of 23 pelvic landmarks were localized and registered. Tested modalities of registration procedure differed in method, reference bodies and number of reference objects. Modalities were compared by achieved precision of registration. The software tool was developed to perform registration and data analyses including individual registration error evaluation. The automatic registration with vertebra L5 as reference has been found optimal. The study has demonstrated benefits associated with processing ofMRI data in terms of high detection reliability of pelvic configuration. The precision of MRI data processing, tested in the study, may contribute to the enhanced accuracy of MRI data registration, easier data manipulation and analysis.
Název v anglickém jazyce
Image Registration Procedure Used in Intrasubject Comparison of Pelvic Configuration
Popis výsledku anglicky
The objective of the study was to prove magnetic resonance imaging (MRI) as suitable instrument for exploring displacements within the bony pelvis induced by altered pelvic floor muscle characteristics. Repeated MRI of 14 females was performed. Coordinates of 23 pelvic landmarks were localized and registered. Tested modalities of registration procedure differed in method, reference bodies and number of reference objects. Modalities were compared by achieved precision of registration. The software tool was developed to perform registration and data analyses including individual registration error evaluation. The automatic registration with vertebra L5 as reference has been found optimal. The study has demonstrated benefits associated with processing ofMRI data in terms of high detection reliability of pelvic configuration. The precision of MRI data processing, tested in the study, may contribute to the enhanced accuracy of MRI data registration, easier data manipulation and analysis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advances in Computational & Experimental Engineering and Sciences, Proceedins of ICCES'09
ISBN
978-0-9717880-9-1
ISSN
1933-2815
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Tech Science Press
Místo vydání
Norcross, GA
Místo konání akce
Phuket
Datum konání akce
8. 4. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—