Image Registration Procedure Used in Intrasubject Comparison of Pelvic Configuration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F09%3A00161423" target="_blank" >RIV/68407700:21220/09:00161423 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Image Registration Procedure Used in Intrasubject Comparison of Pelvic Configuration
Popis výsledku v původním jazyce
The objective of the study was to prove magnetic resonance imaging as suitable instrument for exploring the nature and amplitude of displacements within the bony pelvis induced by asymmetrically altered pelvic floor muscle characteristics. Repeated MR imaging of 14 females was performed. Spatial coordinates of 23 pelvic landmarks were localized in each subject and registered by interactive and automatic procedures. Modalities of registration procedure were tested and compared by the precision of registration. The software tool was developed to perform registrations and data analyses including individual registration error evaluation. The automatic registration with vertebra L5 as reference has been found optimal. The study has demonstrated benefits associated with processing of MRI data in terms of high detection reliability of pelvic configuration.
Název v anglickém jazyce
Image Registration Procedure Used in Intrasubject Comparison of Pelvic Configuration
Popis výsledku anglicky
The objective of the study was to prove magnetic resonance imaging as suitable instrument for exploring the nature and amplitude of displacements within the bony pelvis induced by asymmetrically altered pelvic floor muscle characteristics. Repeated MR imaging of 14 females was performed. Spatial coordinates of 23 pelvic landmarks were localized in each subject and registered by interactive and automatic procedures. Modalities of registration procedure were tested and compared by the precision of registration. The software tool was developed to perform registrations and data analyses including individual registration error evaluation. The automatic registration with vertebra L5 as reference has been found optimal. The study has demonstrated benefits associated with processing of MRI data in terms of high detection reliability of pelvic configuration.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Conference on Computational & Experimental Engineering and Sciences
ISSN
1933-2815
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—