We have built a liquid circuit for the testing of SPD cooling structures of ALICE detector. Circuit is used for the assessment of temperature performance of light carbon fiber structures prototypes. The cooling is single-phase with the water used as a coolant. Flow is regulated by needle valve and constant temperature of inlet water is maintained by heat exchanger in thermostatic bath. The flow is measured by turbine flow-meter together with calibrated frequency-voltage converter, number of platinum temperature sensors are installed in the circuit measuring the temperature of the water entering and exiting the structures. The structures prototyped can carry up to 8 NTC temperature sensors and the surface temperature distribution is evaluated by thermo-camera. Data from the sensors can be collected by one or two ELMB modules. The measured data are visualized and stored in the project which we have developed in the SCADA software PVSSII.
Název v anglickém jazyce
Liquid circuit for SPD prototype
Popis výsledku anglicky
We have built a liquid circuit for the testing of SPD cooling structures of ALICE detector. Circuit is used for the assessment of temperature performance of light carbon fiber structures prototypes. The cooling is single-phase with the water used as a coolant. Flow is regulated by needle valve and constant temperature of inlet water is maintained by heat exchanger in thermostatic bath. The flow is measured by turbine flow-meter together with calibrated frequency-voltage converter, number of platinum temperature sensors are installed in the circuit measuring the temperature of the water entering and exiting the structures. The structures prototyped can carry up to 8 NTC temperature sensors and the surface temperature distribution is evaluated by thermo-camera. Data from the sensors can be collected by one or two ELMB modules. The measured data are visualized and stored in the project which we have developed in the SCADA software PVSSII.
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LA08015" target="_blank" >LA08015: Spolupráce ČR s CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
ALICE_LIQCIR
Číselná identifikace
—
Technické parametry
okruh na ploše cca 3x3m, řídicí PLC alokováno v servisní místnosti
Ekonomické parametry
100 000 Kč
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
68407700
Název vlastníka
ČVUT v Praze, FS
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Požadavek na licenční poplatek
Z - Poskytovatel licence na výsledek nepožaduje v některých případech licenční poplatek
Adresa www stránky s výsledkem
—