Measurement of O2 in the combustion chamber of a pulverized coal boiler
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00201727" target="_blank" >RIV/68407700:21220/12:00201727 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of O2 in the combustion chamber of a pulverized coal boiler
Popis výsledku v původním jazyce
Operational measurements of the O2 concentrations in the combustion chamber of a pulverized coal boiler are not yet common practice. Operators are generally satisfied with measuring the O2 concentration in the second pass of the boiler, usually behind the economizer, where a flue gas sample is extracted for analysis in a classical analyzer. A disadvantage of this approach is that there is a very weak relation between the measured value and the condition in specific locations in the fireplace, e.g. the function of the individual burners and the combustion process as a whole. A new extraction line was developed for measuring the O2 concentration in the combustion chamber. A planar lambda probe is used in this approach. The extraction line is designed to get outputs that can be used directly for diagnosis or management of the combustion in the boiler.
Název v anglickém jazyce
Measurement of O2 in the combustion chamber of a pulverized coal boiler
Popis výsledku anglicky
Operational measurements of the O2 concentrations in the combustion chamber of a pulverized coal boiler are not yet common practice. Operators are generally satisfied with measuring the O2 concentration in the second pass of the boiler, usually behind the economizer, where a flue gas sample is extracted for analysis in a classical analyzer. A disadvantage of this approach is that there is a very weak relation between the measured value and the condition in specific locations in the fireplace, e.g. the function of the individual burners and the combustion process as a whole. A new extraction line was developed for measuring the O2 concentration in the combustion chamber. A planar lambda probe is used in this approach. The extraction line is designed to get outputs that can be used directly for diagnosis or management of the combustion in the boiler.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F538" target="_blank" >FR-TI1/538: Technologie měření pro pokročilé řízení spalovacích procesů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
35-38
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84864435584