INFLUENCE OF DATA QUALITY ON PIV MEASUREMENT ACCURACY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00205611" target="_blank" >RIV/68407700:21220/12:00205611 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1615/JFlowVisImageProc.2013003304" target="_blank" >http://dx.doi.org/10.1615/JFlowVisImageProc.2013003304</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1615/JFlowVisImageProc.2013003304" target="_blank" >10.1615/JFlowVisImageProc.2013003304</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
INFLUENCE OF DATA QUALITY ON PIV MEASUREMENT ACCURACY
Popis výsledku v původním jazyce
The influence exerted by the quality of the data obtained using the Particle Image Velocimetry (PIV) method on the resultant measurement accuracy is considered. The accuracy of measurements using PIV is checked with the help of two synthetic tests: the Uniform Flow Test (UFT) and the Couette Flow Test (CFT). The paper defines the main parameters which enable the quality of the data measured to be described . Based on the synthetic tests done, the conclusion indicates the recommended range for certain main parameters so that the resultant measurement accuracy using PIV is higher than one tenth of a pixel. Ideally, the aim of the paper is to do a comprehensive survey of the influence exerted by the measured data quality on the resultant measurement accuracy with the use of the PIV method.
Název v anglickém jazyce
INFLUENCE OF DATA QUALITY ON PIV MEASUREMENT ACCURACY
Popis výsledku anglicky
The influence exerted by the quality of the data obtained using the Particle Image Velocimetry (PIV) method on the resultant measurement accuracy is considered. The accuracy of measurements using PIV is checked with the help of two synthetic tests: the Uniform Flow Test (UFT) and the Couette Flow Test (CFT). The paper defines the main parameters which enable the quality of the data measured to be described . Based on the synthetic tests done, the conclusion indicates the recommended range for certain main parameters so that the resultant measurement accuracy using PIV is higher than one tenth of a pixel. Ideally, the aim of the paper is to do a comprehensive survey of the influence exerted by the measured data quality on the resultant measurement accuracy with the use of the PIV method.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TE01020020" target="_blank" >TE01020020: Centrum kompetence automobilového průmyslu Josefa Božka</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Flow Visualization and Image Processing
ISSN
1065-3090
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
215-230
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—