Optimizing air supply into data rack through the floor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00210942" target="_blank" >RIV/68407700:21220/13:00210942 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimizing air supply into data rack through the floor
Popis výsledku v původním jazyce
When designing a modern data center it is possible to make use of several basic arrangements. Most frequently, it is a data rack configuration known as hot/cool aisle. Another option is that the cooled air is supplied to each data rack within a double floor and, in case of very complicated applications the closed cooling systems of one data rack cabinet are used. The purpose of this paper is to optimize, in cooperation with Conteg s.r.o. company, the cooled air supply within the double floor directly into the interior of the data rack with the aim of reducing the total pressure loss and thus increasing the maximum limit of installed power into one data rack. The current solution of the air supply to the data rack is based on using simple "deflectors" of air placed in the lower part of the data rack. The Conteg s.r.o. Company currently offers two solutions. For small data racks with low performance, it offers a solution with a 1U deflector. Data racks that are prepared for higher instal
Název v anglickém jazyce
Optimizing air supply into data rack through the floor
Popis výsledku anglicky
When designing a modern data center it is possible to make use of several basic arrangements. Most frequently, it is a data rack configuration known as hot/cool aisle. Another option is that the cooled air is supplied to each data rack within a double floor and, in case of very complicated applications the closed cooling systems of one data rack cabinet are used. The purpose of this paper is to optimize, in cooperation with Conteg s.r.o. company, the cooled air supply within the double floor directly into the interior of the data rack with the aim of reducing the total pressure loss and thus increasing the maximum limit of installed power into one data rack. The current solution of the air supply to the data rack is based on using simple "deflectors" of air placed in the lower part of the data rack. The Conteg s.r.o. Company currently offers two solutions. For small data racks with low performance, it offers a solution with a 1U deflector. Data racks that are prepared for higher instal
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010184" target="_blank" >TA01010184: Výzkum a vývoj řešení rozvaděčových, chladících a transportních systémů pro datová centra</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
8th World Conference on Experimental Heat Transfer, Fluid Mechanics and Thermodynamics Book of Abstrakt
ISBN
978-972-8620-23-3
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
74
Název nakladatele
Instituto Superior Técnico/Instituto de Telecomunicaçoes Portugal
Místo vydání
Lisbon
Místo konání akce
Lisboa
Datum konání akce
16. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—