LHCb experimental setup (air cooling option)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00211093" target="_blank" >RIV/68407700:21220/13:00211093 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LHCb experimental setup (air cooling option)
Popis výsledku v původním jazyce
We have built a testing cooling prototype apparatus for the LHCB SciFi particle detector endcap mockups. This detector is currently under development and it is foreseen to be used in the LHC accelerator in CERN. The silicon photomultipliers in the endcapmodules needs to be cooled and for that purpose a different designs of air heat exchangers were tested. The AIRCOOLER_II, which was developed at the CTU Department of Applied Physics, was the core of the test setup. The AIRCOOLER_II is an arrangement ofvortex tubes producing a stream of air as cold as -50°C. The input compressed air was passing through a Donaldson Ultrapac 2000 type 0050 dryer and its flow was measured using the Azbil 0-500l/min flow meter. The produced cold air flow was measured by the Red-Y Smart flow meter. AIRCOOLER itself was equipped with three SensorTechnics pressure sensors and with seven temperature sensors. There were at least ten temperature sensors placed in each mockup with inner heat exchanger and photom
Název v anglickém jazyce
LHCb experimental setup (air cooling option)
Popis výsledku anglicky
We have built a testing cooling prototype apparatus for the LHCB SciFi particle detector endcap mockups. This detector is currently under development and it is foreseen to be used in the LHC accelerator in CERN. The silicon photomultipliers in the endcapmodules needs to be cooled and for that purpose a different designs of air heat exchangers were tested. The AIRCOOLER_II, which was developed at the CTU Department of Applied Physics, was the core of the test setup. The AIRCOOLER_II is an arrangement ofvortex tubes producing a stream of air as cold as -50°C. The input compressed air was passing through a Donaldson Ultrapac 2000 type 0050 dryer and its flow was measured using the Azbil 0-500l/min flow meter. The produced cold air flow was measured by the Red-Y Smart flow meter. AIRCOOLER itself was equipped with three SensorTechnics pressure sensors and with seven temperature sensors. There were at least ten temperature sensors placed in each mockup with inner heat exchanger and photom
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LG13031" target="_blank" >LG13031: Spolupráce ČR s CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
LHCb_Aircooler_II_2013
Číselná identifikace
—
Technické parametry
Rack 1m x 2m x 1m; Aicooler_II; DAQ systém a senzory; zásobník tlak. vzduchu
Ekonomické parametry
100 000 Kč
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
68407700
Název vlastníka
ČVUT FSI
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Požadavek na licenční poplatek
Z - Poskytovatel licence na výsledek nepožaduje v některých případech licenční poplatek
Adresa www stránky s výsledkem
—