Possible explanations of hysteresis at hydraulic characteristics in pipes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F14%3A00221480" target="_blank" >RIV/68407700:21220/14:00221480 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Possible explanations of hysteresis at hydraulic characteristics in pipes
Popis výsledku v původním jazyce
Hysteresis observed at repeated loading/unloading cycles when measuring mechanical properties may be a manifestation of genuine material characteristics but it can be also an instrumentation artefact. This article was motivated by observed hysteresis ofa hydraulic characteristic in pumping a native polymeric material through a pipe at a gradually increasing and decreasing flowrate. The system was without recirculation and the same fresh liquid was pumped into the pipeline during increasing/decreasing phase, nevertheless the recorded pressure drop during the increasing phase was greater than the pressure at decreasing phase at the same flowrate. A possible explanation can be based upon the temperature dependent viscosity: during the flowrate ascendingphase the test pipe is filled by a colder liquid corresponding to previous less intensive viscous heating (therefore viscosity and pressure drop is greater then during the subsequent phase of decreasing flowrate). Another possibility is t
Název v anglickém jazyce
Possible explanations of hysteresis at hydraulic characteristics in pipes
Popis výsledku anglicky
Hysteresis observed at repeated loading/unloading cycles when measuring mechanical properties may be a manifestation of genuine material characteristics but it can be also an instrumentation artefact. This article was motivated by observed hysteresis ofa hydraulic characteristic in pumping a native polymeric material through a pipe at a gradually increasing and decreasing flowrate. The system was without recirculation and the same fresh liquid was pumped into the pipeline during increasing/decreasing phase, nevertheless the recorded pressure drop during the increasing phase was greater than the pressure at decreasing phase at the same flowrate. A possible explanation can be based upon the temperature dependent viscosity: during the flowrate ascendingphase the test pipe is filled by a colder liquid corresponding to previous less intensive viscous heating (therefore viscosity and pressure drop is greater then during the subsequent phase of decreasing flowrate). Another possibility is t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-23482S" target="_blank" >GA14-23482S: Tepelné, elektrické a reologické vlastnosti kolagenní hmoty</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CHISA 2014
ISBN
978-80-02-02555-9
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
Orgit
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
23. 8. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—